Setting Rise Time Parameter; Setting Adaptive Parameters - Miller Electric Welder Owner's Manual

Operating instructions and programming instructions
Table of Contents

Advertisement

15-2. Setting Rise Time Parameter

NOTE
Access
Control
Display
> Process
Sequence
SharpArc
Card

15-3. Setting Adaptive Parameters

Access
Control
Display
Press Mode
Select
>Process
Sequence
SharpArc
Card
OM-196 188 Page 120
Maximum Rise Time setting will make the welding power source go to its
maximum output in the maximum amount of time (1250 amperes per millisecond).
> Rise Time
Adaptive
AutoConfig
Retract
Increase/Decrease
Power
> Prg 1
Switch
Pulse
035" Steel
Argon – Oxy
Rise Time
> Adaptive
AutoConfig
Retract
Power
> Prg 1
Switch
Pulse
035" Steel
Argon – Oxy
1
A/ms
> 800
A/ms
> 680
Mode
Or
Select
Go To
Section 15-4
1
> Adapt A
Increase/
Decrease
> Adapt B
Mode
Or
Select
Go To
Section 15-4
1
Rise Time Display
Setting is depend on desired arc
characteristics. Make a sample
weld after each setting until desired
arc characteristics are obtained.
Use Increase or Decrease button to
change setting.
Range is 250 to 1250 amperes per
millisecond (A/ms).
Press Mode Select button to go to
next parameter or cycle power off
and back on at power switch to sav-
e setting and exit Control menu.
1
Adaptive Parameter Display
Settings allow user to choose be-
tween two adaptive programs, A or
B.
Use Increase or Decrease button to
change setting.
Press Mode Select button to go to
next parameter or cycle power off
and back on at power switch to sav-
e setting and exit Control menu.
.
For more detailed information
on A vs. B adaptive programs,
consult factory specialist.