Setting Weld Sequence Display; Setting Crater Sequence Display - Miller Electric Welder Owner's Manual

Operating instructions and programming instructions
Table of Contents

Advertisement

9-3. Setting Weld Sequence Display

Set Desired Weld
Sequence Trim
Increase/
Decrease
Set Desired Weld Sequence
Wire Feed Speed
Increase/
Decrease

9-4. Setting Crater Sequence Display

1
>Cratr
0.00 Sec
50 Trim
200 IPM
> Cratr
0.20 Sec
60 Trim
150 IPM
Parameter
Select
Increase
Proceed to next Section.
1
Weld
> 50 Trim
200 IPM
Parameter
Select
Weld
60 Trim
> 200 IPM
Parameter
Select
> Weld
60 Trim
Increase
300 IPM
Proceed to next Section.
Cratr
> 0.00 Sec
50 Trim
200 IPM
Set Desired
Parameter
Time
Select
Increase/
Decrease
Cratr
0.20 Sec
60 Trim
> 150 IPM
Set Desired Wire
Parameter
Feed Speed
Select
Increase/
Decrease
Parameter
Select
Cratr
0.20 Sec
> 50 Trim
200 IPM
Set Desired
Trim
Increase/
Decrease
1
Weld Parameters Display
Parameter ranges are as follows:
Trim (Arc Length), 0-99
Wire Feed Speed, 50-780 Inches
Per Minute, IPM
Go to Section 9-4.
1
Crater Parameters Display
Parameter ranges are as follows:
Seconds, 0-2.50 Sec. If value set is
zero (0), there is no Crater
sequence.
Trim (Arc Length), 0-99
Wire Feed Speed, 50-780 Inches
Per Minute, IPM
Go to Section 9-5.
OM-196 188 Page 89