3-5. Weld Output Terminals And Selecting Cable Sizes

Positive
Positive
(+)
(+)
Negative
Negative
(–)
(–)
Ref. 801 914-A
Ref. 801 914-A
2
*Weld cable size (mm
) is based on either a 4 volts or less drop or a current density of at least 300 circular mils per ampere.

3-6. 115 Volts AC Duplex Receptacle And Circuit Breakers

4
OM-196 188 Page 14
Total Cable (Copper) Length In Weld Circuit Not Exceeding
30 m (100 ft) Or Less
Welding
10 – 60%
60 – 100%
Amperes
Duty Cycle
Duty Cycle
100
25
150
35
200
35
250
35
300
50
350
55
400
55
500
70
600
95
1
45 m
60 m
(150 ft)
(200 ft)
25
25
35
35
35
50
35
50
55
50
55
70
55
70
95
70
95
120
70
95
120
95
120
2-70
120
2-70
2-95
2
3
70 m
90 m
105 m
(250 ft)
(300 ft)
(350 ft)
10 – 100% Duty Cycle
35
50
55
55
70
95
70
95
120
95
120
2-70
120
2-70
2-95
2-70
2-95
2-95
2-70
2-95
2-120
2-95
2-120
3-95
2-120
3-95
3-120
1
115 V 10 A AC Receptacle
Power is shared between duplex
receptacle and internal 14 socket
receptacle.
2
Circuit Breaker CB1
3
Circuit Breaker CB2
CB1 protects duplex receptacle
and 115 volts ac portion of internal
14
socket
receptacle
overload.
Press button to reset breaker.
CB2 protects 24 volts ac portion of
internal 14 socket receptacle from
overload.
Press button to reset breaker.
4
Circuit Breaker CB1
CB1 protects the motor control
circuitry from overload. If CB1 trips,
the wire drive motor is inoperative.
Press button to reset breaker.
120 m
(400 ft)
55
95
120
2-70
2-95
2-120
2-120
3-95
3-120
S-0007E
from
802 748