IDEAL COMBI ESP 24 Pocket Manual page 61

Hide thumbs Also See for COMBI ESP 24:
Table of Contents

Advertisement

FLUE
Horizontal flue terminal (0.6m long)
+ 2 x Flue 90° elbow kit (60/100)
Horizontal flue terminal (0.6m long)
+ 4 x Flue extension 1m (pack D)
+ 2 x Flue 90° elbow kit (60/100)
Horizontal flue terminal (0.6m long)
+ 6 x Flue extension 1m (pack D)
+ 2 x Flue 90° elbow kit (60/100)
Horizontal flue terminal (0.6m long)
+ 7 x Flue extension 1m (pack D)
+ 2 x Flue 90° elbow kit (60/100)
HORIZONTAL
FLUE WITH
2 X 90° ELBOW.
NOTE:
Lengths are sum of all straight lengths
between outside edge of turret to
outside wall face.
Numbers of extension D packs give flexibility
of lengths of straight at either side of elbow.
Where extension D packs are cut to length,
flared end connector must be retained.
IDEAL
MAXIMUM STRAIGHT
PART NO.
FLUE LENGTH (MM)
208171
2 x 203130
208171
4356 (38 max length 4m.
4 x 203129
+ 2x 90° elbow)
2 x 203130
208171
6286 (33 max length 6m.
6 x 203129
+ 2x 90° elbow)
2 x 203130
208171
7000 (26 models max length 7m.
7 x 203129
+ 2x 90° elbow)
2 x 203130
61
556

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents