TECHNICAL SPECIFICATION.
Weight (packaged) kg
Max installation weight kg
CH output (kW) min/max
@ 70°C
CH output (kW) min/max
@ 40°C
DHW output (kW) max
DHW flow rate l/min.
35°C rise
SEDBUK rating (2005)
SEDBUK rating
(2009/2012) %
NOx classification
Adjustable to LPG
Condensing boiler
Seasonal space heating
efficiency class
Rated heat output kW
Seasonal space heating
energy efficiency η
son
Sound power level,
indoors L
dB
WA
Water heating energy
efficiency class
Multiple flue kits available.
** Each 90° elbow used is at the expense of 1000mm of straight flue run,
and each 45° elbow is used at the expense of 600mm of straight flue run.
† Typical combined primary and secondary length. See installation instructions
for more details. Note: The Flue Deflector Kit is used at the expense
of 1000mm of straight flue run.
CODE COMBI
ES 26
39.5
34.7
4.8 - 24.2
5.1 - 25.6
26.1
10.7
91
89.0
CLASS 5
No
Yes
A
24
93
%
45
A
CODE COMBI
ES 33
39.7
34.9
6.1 - 24.2
6.4 - 25.6
32.7
13.4
91.1
89.0
CLASS 5
No
Yes
A
24
93
45
A
17
CODE COMBI
ES 38
39.7
34.9
7.1 - 24.2
7.5 - 25.6
38.2
15.7
91
88.9
CLASS 5
Yes
Yes
A
24
93
44
A