TECHNICAL SPECIFICATIONS
Power output
Supply voltage
Frequency
Absorbed power
Absorbed current
Motor rotation speed
Capacitor
Intermittent service
Rated torque
Gear ratio
Running speed
Oil temperature
Oil type (AGIP ROTRA THT)
Protection standard
Weight. Mec 200 Vertical
Weight. Mec 200 Horizontal
Max. gate weight
Duty cycle
Power supply
Voltage output
Low voltage output
E.M. max. power output
Line fuses
Secondary fuses
Logic switching
Box dimensions
Protection standard
Elesta relay marking
SECTION VIEW WITH BRAKE (on request) AND RELEASE KEY
Drwg. No. 3404
PIC. 12
ELECTRIC MOTOR
SINGLE-PHASE
THREE-PHASE
0.37 KW (0.5 HP)
0.37 KW (0.5 HP)
230 V
50/60 Hz
510 W
2.4 A
1˙380 rpm
20 μF
S3
MEC 200 GEAR BOX
40 Nm
1:32
9.6 m/1'
-20°C +80°C
W 80 - Kg 0.22
IP 557
19 Kg
19.5 Kg
400 Kg
No. of complete cycles per year (8 hours' service per day): 131˙000 cycles
ELPRO 10 PLUS ELECTRONIC PANEL
230 / 400 V
230 V - 25 W
24 V - 10 W
1˙100 W
5 A
1A - 630 mA
Open-Stop-Close
290x205x140
IP 437
VDE-CSA-DEMCO-SEV
10 A 230 V
4 A 400 V
ADJUSTMENT
SPANNER E17
ANTI-CLOCKWISE
TO RELEASE
SINGLE-PHASE
0.73 KW (1 HP)
230/400 V
230 V
50/60 Hz
50/60 Hz
575 W
1˙130W
2.1-1.2 A
5.7 A
1˙380 rpm
1˙380 rpm
30 μF
S3
S3
40 Nm
80 Nm
1:32
1:32
9.6 m/1'
9.6 m/1'
-20°C +80°C
-20°C +80°C
W 80 - Kg 0.22
W 80 - Kg 0.22
IP 557
IP 557
18 Kg
23 Kg
18.5 Kg
23.5 Kg
450 Kg
800 Kg
25 s Open - 30 s Dwell - 25 s Close
Time for one complete cycle 80 s
No. of complete cycles Open-Dwell-Close: 45/Hour
Power transformer
Magnetic core
Voltage
Outputs
Frequency
Insulation
Main switch
Contact rating
BUILT-IN AIR-COOLED BRAKE
(on request)
THREE-PHASE
THREE-PHASE
0.73 KW (1 HP)
1.1 KW (1.5 HP)
230/400 V
230/400 V
50/60 Hz
50/60 Hz
1˙030 W
1˙500 W
3.7-2.2 A
5.1-3 A
1˙380 rpm
1˙380 rpm
S3
S3
80 Nm
110 Nm
1:32
1:32
9.6 m/1'
9.6 m/1'
-20°C +80°C
-20°C +80°C
W 80 - Kg 0.22
W 80 - Kg 0.22
IP 557
IP 557
21 Kg
25 Kg
21.5 Kg
25.5 Kg
850 Kg
1˙200 Kg
20 VA
1.5 W / 0.5 thick
0-230 V
0-12-18-24 V
50-60 Hz
4 Kv x 1'
T215K Mark SAA
15A 250 V AC
13
Need help?
Do you have a question about the MEC 200 and is the answer not in the manual?