Fuel System
b. Disconnect connector (B), and measure the
resistance between connector (A) and chassis
ground, and between (B1) and chassis ground as
shown in [FIG. 7].
The measured resistance between connector (B1)
and chassis ground is 1Ω or less. The short to
ground circuit is between terminal 1 of connector
(C) and terminal 1 of connector (B1).
Actuation test
MIL(ENGINE CHECK)
FUEL PUMP RELAY
ELECTRIC VGT CONTROL ACTUATOR
FUEL PRESSURE REGULATOR VALVE(HP PUMP SIDE)
RAIL PRESSURE REGURATOR VALVE(COMMON RAIL SIDE)
Items
97
Test Condition
ACTUATION TEST/ IG ON /ENGINE RUN
ACTUATION TEST/ IG ON /ENGINE RUN
ACTUATION TEST/ IG ON /ENGINE RUN
ACTUATION TEST/ IG ON /ENGINE RUN
ACTUATION TEST/ IG ON /ENGINE RUN
General Information