Chapter 6
1) Roll media
If roll media is used up, load new roll media.
2) Media sensor
Select [SERVICE MODE]>[I/O DISPLAY] to check for normal operation. If the operation is abnormal, replace the media sensor.
3) Replace the main controller PCB.
6.1.4.11 03130031-260E Gap detection error
<Cause>
A detection error occurred due to damaged hardware, uncorrected gap, or damaged correction data.
<Probable fault location>
Multi sensor, head relay PCB, carriage relay PCB or main controller PCB
<Countermeasure>
1) Cable continuity check
If continuity of the cable between the multi sensor and the head relay PCB is abnormal, replace the cable.
2) Replace the multi sensor.
3) Cable continuity check
If continuity of the cable between the head relay PCB and the carriage relay PCB is abnormal, replace the cable.
4) Replace the head relay PCB.
5) Cable continuity check
If continuity of the cable between the carriage relay PCB and the main controller PCB is abnormal, replace the cable.
6) Replace the carriage relay PCB.
7) Replace the main controller PCB.
6.1.4.12 03130031-260F Gap adjustment error
<Cause>
Gap reference surface error (This error occurs only in the service mode.)
<Probable fault location>
Multi sensor base
<Countermeasure>
1) Replace the multi sensor base.
6.1.4.13 03130031-2F13 A/D Converter external trigger output stopped
<Cause>
Defective main controller PCB
<Probable fault location>
Main controller PCB
<Countermeasure>
1) Turn off the printer, and then turn it off again.
2) Replace the main controller PCB.
6.1.4.14 03130031-2F14 ASIC Register cannot be written.
<Cause>
A main controller PCB firmware error occurred.
<Probable fault location>
Main controller PCB
<Countermeasure>
1) Turn off the printer, and then turn it off again.
2) Replace the main controller PCB.
6.1.4.15 03130031-2F16 Mist fan error
<Cause>
Mist fan rotation could not be detected during mist fan rotation.
<Probable fault location>
Mist fan or main controller PCB
<Countermeasure>
1) Replace the mist fan.
2) Replace the main controller PCB
6.1.4.16 03130031-2F17 Suction fan error
<Cause>
When the suction fan was driven, the lock signal was detected for more than the specified time.
<Probable fault location>
Suction fan or main controller PCB
<Countermeasure>
1) Suction fan
Select [SERVICE MODE]>[FUNCTION]>[PLATEN FAN] to check the suction fan for normal operation. If the operation is abnormal, replace the suction fan.
2) Replace the main controller PCB.