Specifications; Electricity Supply; Gas Supply - Southbend P36N-TTT Owner's Manual

Range-top base-oven wendy’s gas range
Table of Contents

Advertisement

W
'
G
R
ENDY
S
AS
ANGE
S
PECIFICATIONS
Local codes regarding installation vary greatly from one area to another. The National Fire Protection
Association, Inc. states in its NFPA 96 latest edition that local codes are the "authority having
jurisdiction" when it comes to installation requirements for equipment. Therefore, installations should
comply with all local codes.
Southbend reserves the right to change specifications and product design without notice. Such
revisions do not entitle the buyer to corresponding changes, additions, or replacements for previously
purchased equipment.
This product is intended for commercial use only, not for household use.
The installation must conform with local codes, or in the absence of local codes, with the National
Fuel Gas Code, ANSI Z223.1, Natural Gas Installation Code, CAN/CGA-B149.1, or the Propane
Installation Code CAN/CGA-B149.2, as applicable, including:
1. The appliance and its individual shutoff valve must be disconnected from the gas supply piping
system during any pressure testing of that system at test pressures in excess of 1/2 psi (3.45
kPa).
2. The appliance must be isolated from the gas supply piping system by closing its individual manual
shutoff valve during any pressure testing of the gas supply piping system at test pressures equal
to or less than 1/2 psi (3.45 kPa).

ELECTRICITY SUPPLY

Convection ovens require connection to a supply of electricity. The appliance, when installed, must be
electrically grounded in accordance with local codes, or in the absence of local codes, with the National
Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code, CSA C22.2, as applicable. An electrical
diagram is located on the side of the control panel assembly (see drawing on page 33). Electrical diagrams
can also be found in this manual beginning on page 35.
Power Option
120/60/1
208/60/1
240/60/1
240/50/1
Ovens ordered with the 120V power option are equipped with a standard 120V single-phase plug with a
ground prong.
Ovens with other power options have a terminal block on the rear of the oven that must be wired to the
power supply.

GAS SUPPLY

A serial plate located inside the lower front panel of the oven base indicates the type of gas the unit is
equipped to burn. All Southbend equipment is adjusted at the factory. Check type of gas on serial plate.
These models are design-certified for operation on natural or propane gases. For natural gas, the regulator
is set to deliver a 6" (152mm) W.C. pressure to the manifold. For propane gas, it is set to deliver 10"
(254mm) W.C.
O
WNER
Power Type
120 Volts, 60 Hz, Single Phase
190-219 Volts, 60 Hz, Single Phase
220-240 Volts, 60 Hz, Single Phase
208-240 Volts, 50 Hz, Single Phase
'
M
1195747
S
ANUAL
NOTICE
Maximum Amps
S
PECIFICATIONS
7.9
4.3
3.8
6.0
P
5
AGE

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tvgs/12wc