Restaurant range 4 open burners, 24” wide griddle, 2 space saver oven (2 pages)
Summary of Contents for Southbend C0300HT
Page 1
1100 Old Honeycutt Road . Fuquay-Varina, NC 27526 (919) 552-9161 . FAX (919) 552-9798 . (800) 348-2558 Middleby Corp. Service Hot Line (800) 238-8444 (after hours) $18.00 A MIDDLEBY COMPANY INSTALLATION MODEL: C0300HT AND CO301 HT A WARNING service, or maintenance can cause property damage, operation and maintenance...
You will find that your new equipment, like all Southbend equipment, est standards in the industry. Each piece of Southbend equipment is carefully engineered laboratory tests and field installations. With proper care and field maintenance, free operation. For best results, read this manual carefully.
SAFETY PRECAUTIONS Before installing and operating this equipment, be sure everyone involved in its operation is fully trained and aware of precau- tions. Accidents and problems can be caused by failure to follow fundamental rules and precautions. The following symbols, found throughout this manual, alert you to potentially dangerous conditions to the operator, service personnel, or to the equipment.
Page 4
WENDY’S GAS RANGE WITH CONVECTION FRONT VIEW TOP VIEW Dimensions: MODEL Width Depth ’ WENDY’S 36.5” 41.00” 8” 30” 29.375” (927) (1042) (203) (762) (746) ,RANGE OVEN INTERIOR MODEL Depth Height Width WENDY’S 26.125” 21.75” 14.25” (552) GAS RANGE (664) (362) UTILITY INFORMATION: GAS-...
Page 5
WENDY’S CHILI RANGE TOP VIEW Dimensions: MODEL Width Depth ’ WENDY’S 36.5” 41.00” 8” 30” 29.375” GAS RANGE (927) (1042) (203) (762) (746) OVEN INTERIOR MODEL Width Depth WENDY’S 26.125” 21.75” GAS RANGE (664) UTILITY INFORMATION: GAS - Total 85,000 BTU. One 3/4” flex hose male connection. (for location, see drawing above items ‘I”...
(below). Be sure that the input voltage and phase match the requirements A positive ground connection is essential. Southbend reserves the right to change specifications not entitle the buyer to corresponding chased equipment. These procedures must be followed by qualified personnel or warranty will be void.
GAS CONNECTION: The Serial Plate is located inside unit behind kick panel item “B” on figure 1. It indicates the type of gas the unit is equipped to burn. All Southbend equipment is adjusted at the factory. These models are design-certified for operation on natural or propane gases.
Page 8
If applicable, the vent line from the gas appliance pressure regulator shall be installed to the outdoors in accordance with local codes, or in the absence of local codes, with the National Fuel Gas Code, ANSI 2223.1, Natural Gas Installation Code, CAN/CGA-B149.1, B149,2, as applicable.
Page 9
ITEM PART NUMBER 1176423 114-6303 Local codes regarding installation vary greatly from one area to another. Association, Inc. states in its NFPA 96 latest edition that local codes are the “authority having jurisdic- tion” when it comes to installation with all local codes. EXHAUST FANS AND CANOPIES: is recommended...
Page 10
4. Locate box marked “legs” or “casters.” A gas pressure regulator is supplied and already installed on the incoming gas line. If legs or casters are not received, contact your Southbend Sales Representative. Please have your model and serial number ready when you call.
Page 11
ITEM PARTNUMBER * 1174260 Leg package consists of four legs. Screws, leg pad, and lock washers are not included in leg package. * Not shown - these are optional. The leg pad hardware will stay the same. To avoid accidental aas disconnection For an appliance equipped with casters, the installation should be made with a connector that complies with the standard for connectors for movable gas appliances, ANSI 221.69 or connec- tors for movable gas appliances, CAN/CGA-6.1 6, and a quick-disconnect...
Adequate restraining means “must be attached to rear of appliance when installed.” codes as applicable. For units not equipped with flame safety devices, be sure all valves are turned off I)TioT to disconnecting. necting, be sure all valves are turned off and all pilots are lit. INSTALLATION INSTRUCTIONS 1.
Page 13
GRIDDLES: New griddles should be carefully tempered and maintained to avoid possible cracking and/or warping. new griddle, first wipe it clean. Next, light all griddle burners and set thermostats ally bring griddle to frying temperature. to season it. Never allow water on a hot griddle and never wash it with soap and water. Use a Norton Alundum (or equivalent) quick heat may cause costly damage.
THEORY OF OPERATION LIGHTING, RE-LIGHTING NOTE: When this range has been disconnected wait six minutes before lighting top section. This allows all air to be purged from the range. Refer to figure 6 above when following these instructions. LIGHTING: RANGE CONVECTION OVEN 1.
Page 15
To eliminate aas buildup which could result in exolosion: In the event of main burner ignition failure, a five minute purge period must be observed prior to restablishing ignition source. In the event a gas odor is detected, shut down equipment at the main shut off valve. call the emergency phone number of your gas supplier.
(CONVECTION-TYPE OVEN ONLY): A. FROZEN ENTREE PRODUCTS: Punch holes in lid before heating. lasagna or macaroni and cheese. Use manufacturer’s reduce conventional oven temperature less time than recommended for convection ovens if prepared from frozen in a six pan load. B.
Contact the Authorized Southbend Service Agency for reliable service, dependable advice or other assistance, and for genuine factory parts. Warranty will be void and the manufacturer (A) Service work is performed by other than a qualified technician.
ADJUSTMENTS FIGURE 8 Refer to figure 8 (above). OVEN PILOT: A. Remove the kick panel below the oven door (item “A”). B. Adjust oven pilot flame by turning the adjusting screw on the pilot line valve (item “B”). C. The pilot flame is properly adjusted when it is just large enough to maintain a glowing red color of the flame switch capillary bulb.
TROUBLE SHOOTING GENERAL: PROBLEM - All burners and pilots in unit will not turn on All burners produce excessive carbon deposits Only some burners in a unit produce excessive carbon deposits Only some pilots produce excessive carbon deposits Top burner (not oven) will not come on Top section pilot will not stay ignited...
De-energize all power to equipment before cleaning the equipment. At least twice a year, have your Southbend Authorized Service Agency or another qualified service technician clean and adjust the unit for maximum performance. Consult the Southbend Authorized Parts/Service area. If this is not available, call the Service Department at Southbend,...
Little attention is needed, but if spillage should occur, it may be necessary to clean around pilot areas, air mixer and under burners. Use a wire brush if necessary. Periodically, burners (particularly open top type) should be removed and cleaned. Dry thoroughly before replacing.
Page 22
CONTROL PANEL: The textured control panel should be cleaned with warm water and mild soap. Never use cleaning solvents with a hydro- carbon base. MOTOR: Lubrication information can be found on a permanent label located on motor. DO NOT USE ordinary steel wool as any particles left on the surface will rust. NEVER USE a wire brush, steel or abrasive scouring pad (except stainless), scraper, file or other steel tools.
There is also an Identification Plate mounted to the front left corner of the valve panel that will supply model and serial number. Replacement parts may be ordered either through a Southbend Authorized Parts Distributor or a Southbend Authorized Service Agency.
Page 24
iJRE 9 Refer to figure 9 above. PART NUMBER DESCRIPTION * Item not shown on drawing. PAGE 23...
Page 25
FIGURE Refer to figure IO above. PART NUMBER DESCRIPTION * Item not shown on drawing. PAGE 24...
Should any part thereof become defective as a result of normal use within the period and limits defined below, then at the option of Southbend, such parts will be repaired or replaced by Southbend or its Authorized Service Agency.
Page 27
A product with the Southbend name incorporates the best in durability and low maintenance. and occasional professional service may be necessary to extend the useful life of this unit. When service is needed, contact a Southbend Authorized Service Agency, or your dealer. To avoid confusion, always refer to the model number, serial number, and type of your unit.
Need help?
Do you have a question about the C0300HT and is the answer not in the manual?