Rz25 Scsi Hard Disk Drive Operating Conditions; Rz25 Scsi Hard Disk Drive Nonoperating Conditions - DEC Personal DECstation 5000 User Manual

Hide thumbs Also See for Personal DECstation 5000:
Table of Contents

Advertisement

Equipment Specifications
A.8 RZ25 SCSI Hard Disk Drive Equipment Specifications
Table A–24 RZ25 SCSI Hard Disk Drive Operating Conditions
1
Temperature range
Temperature change rate
Relative humidity
Maximum wet-bulb temperature
Altitude
1
Reduce maximum temperature by 1.8°C for each 1,000 meter (1.0°F for each 1,000 ft) increase in altitude.
Table A–25 RZ25 SCSI Hard Disk Drive Nonoperating Conditions
Temperature range
Temperature change rate
Relative humidity
Maximum wet-bulb temperature
Altitude
A–18 Equipment Specifications
10°C to 55°C (50°F to 131°F)
11°C (20°F) per hour, maximum
8% to 80% noncondensing
26°C (78°F)
300 to 3050 m ( 1000 to 10,000 ft)
40°C to 66°C ( 40°F to 151°F)
20°C (36°F) per hour, maximum
8% to 95% packaged, noncondensing
46°C (115°F) packaged
300 m to 12,200 m ( 1,000 ft to 40,000 ft)