Resolving Camera Issues; Communications; No Camera Features When Starting Camexpert; No Lval - Dalsa Piranha XL PX-HM-16K12B-00-R User Manual

Hide thumbs Also See for Piranha XL PX-HM-16K12B-00-R:
Table of Contents

Advertisement

Resolving Camera Issues

Communications

No Camera Features when Starting CamExpert

If the camera's CamExpert GUI is opened and no features are listed, then the camera may be
experiencing lane lock issues.
While using the frame grabber CamExpert GUI you should be able to see a row of status indicators
below the image area that indicates the status of the CLHS communications. These indicators
include seven lane lock status and a line valid (LVAL) status.
If the status for one or more lane locks is red, then there is likely an issue with the CLHS
connectors at the camera and / or frame grabber. Ensure that the connectors are fully engaged and
that the jack screws are tightened. Ensure that you are also using the recommended cables.

No LVAL

If the LVAL status is red and all lane locks are green, then there may be an issue with the camera
receiving the encoder pulses.
1.
From the Camera CamExpert > Digital I/O Control tab, select Internal Trigger Mode and set the
CamExpert > Camera Control tab Acquisition Line Rate to the maximum that will be used.
2. The trigger signal from the frame grabber will not be used and the LVAL status should now be green.
This will confirm the integrity of the image data portion of the CLHS cabling and connectors.
3. From the Camera CamExpert > Digital I/O Control tab, select External Trigger Mode.
4. From the Frame Grabber CamExpert > Advanced tab, select the Line Sync Source to be Internal Line
Trigger and the Internal Line Trigger frequency to the maximum that will be used.
5. The trigger source is now being generated by the frame grabber and the LVAL status should be green.
This will confirm the integrity of the General Purpose I / O portion of the CLHS cabling and connectors.
6. From the Frame Grabber CamExpert > Advanced tab, select the Line Sync Source to be External Line
Trigger and select the Line Trigger Method to Method 2 under the same tab.
7. From the Frame Grabber CamExpert > External Trigger tab, select External Trigger to be enabled. If LVAL
status turns red, check the following:
a. Is the transport system moving such that encoder pulses are being generated?
b. Has the encoder signal been connected to the correct pins of the I / O connector of the frame
grabber? See the XTIUM frame grabber user manual for details.
c. Do the encoder signal levels conform to the requirements outlined in the XTIUM frame grabber
user manual?

Image Quality Issues

Vertical Lines Appear in Image after Calibration

The purpose of flat field calibration is to compensate for the lens edge roll-off and imperfections in
the illumination profiles by creating a uniform response. When performing a flat field calibration,
the camera must be imaging a flat white target that is illuminated by the actual lighting used in the
application. Though the camera compensates for illumination imperfection, it will also compensate
for imperfections such as dust, scratches, paper grain, etc. in the white reference. Once the white
reference is removed and the camera images the material to be inspected, any white reference
The Piranha XL Camera