Instruction Manual; Cb Technology; Primary Air; Secondary Air - SCAN Basic 5 Assembly And Instruction Manual

Table of Contents

Advertisement

CB Technology (Clean Burning)
Your wood stove is fitted with CB technology. To ensure opti-
mum burning of the gases released by the burning process,
air is guided by a specially developed system. Pre-heated air
is fed into the combustion chamber through the small holes
below the smoke deflector plate. The airflow is driven by the
combustion speed and cannot be regulated.

Primary air

The primary air regulation mechanism is used for lighting the
fire, or to boost the burning process when you put wood on.
The primary air vent can be 25-50% open if you use hard
wood fuel such as oak and beech. You can close the primary
air vent if you use soft wood such as birch or pine for fuel.

Secondary air

Secondary air is pre-heated and fed directly to the fire. At
the same time, the secondary airflow cleans the glass pane
to prevent soot build-up. If you over-restrict the secondary
airflow, soot can build up on the glass pane. The secondary
airflow determines the heat output from your wood stove.
3
2
1
1 Secondary airflow control. Turn the switch to control
the secondary airflow.
2 Primary airflow control. Turn the switch to control the
primary airflow.
3 Product registration number.
4 Ash drawer. Open the glass door to access the ash
drawer which is located below the combustion chamber.
Important note!! Never empty ashes into a flammable
container. Ashes can contain glowing embers long
after you finish using your wood stove.
Setting for normal load
Secondary air %
Primary air %
75
I N S T R U C T I O N M A N U A L
Retaining pins for smoke
deflector platens

Smoke deflector platens

CB Technology

5
Fuel quantity/kg
50
1,5
Smoke deflector platens
The smoke deflector platens are located in the upper part
of the combustion chamber. The platens hold back smoke,
making sure it stays inside the combustion chamber for a
longer time before escaping through the chimney.
This reduces the smoke gas temperature as the gases have
more time to dissipate heat to the wood stove. The smoke
deflector platens must be removed for sweeping; see "Wood
stove maintenance".
Note that the smoke deflector platens are made of porous,
ceramic material, and can break. Exercise care when work-
ing. The smoke deflector platens are subject to wear and
tear, and are not covered by the warranty.
4
Keep the ash drawer closed at all times when the wood
stove is lit.
5 Handle for shaker grate. Your wood stove is fitted with a
shaker grate which empties the ash from the combustion
chamber into the ash drawer when activated.
The shaker grate must be in semi-open position while the
wood stove is lit.
Chimney flue,
Fuel consumption
min. Pa
kg/h
12
Efficiency in %
1,6
73
5

Hide quick links: