Installation

When you install any kind of fireplace or stove, you must
inform the local authorities. The house owner is responsible
for ensuring that all necessary safety measures are obser-
ved, and also responsible for calling in a chimney sweep to
inspect and authorise the installation.

Approval

If you intend to connect your stove to an existing flue, it
would be advisable to contact an authorised Scan dealer, or
a local chimney sweep for advice. These experts will also let
you know if your flue needs renovating.
On connecting to a multiple element flue: Follow the ven-
dor's instructions as applicable to the flue type (e.g. Leca,
Plewa, Icopal, Isokern, Zanda etc.)
No matter whether an authorised Scan dealer installs your
stove, or you do the job yourself, remember that the chim-
ney sweep has to approve the installation before you start
to use it.

Positioning the stove

The woodstove must be set up so that the stove itself, the
smoke gas pipe, and the flue can all be cleaned.
Position in relation to non-flammable
walls
When positioning near a non-flammable wall, keep a mini-
mum distance of 50mm between the rear of the product and
the wall.

Distance to flammable walls

50
350
Distance to furniture: 1000 mm
I N S TA L L AT I O N

Technical data and dimensions

CO Emission at 13% O2:
Efficiency:
Nominal heat output:
Flue temperature:
Smoke output:
Recommended underpressure in smoke
gas connecting piece:
Recommended fuel:
Fuel capacity:
Min./max. heating performance
(vendor specification):
Weight
Smoke gas connecting piece internal diameter:
Smoke gas connecting piece external diameter:
Approved for:
Intermittent fuelling means normal use of a woodstove. In
other words, you should let the fire die down until only the
embers are left, before refuelling.
The Scan Basic 5 was built in compliance with the homolo-
gised product type specified in the Assembly and Instruction
Manual provided with the product.

Accessories:

The following accessories are available for this model
Soapstone cover plates
Lower doo

Fuel storage space

If your stove has a lower door, you must not store flammable
materials in the fuel storage space.
466
* Centre rear outlet
** Height at start of
smoke gas connec-
ting piece on top out-
let
*** Fresh air inlet
425
0,12%
73%
5 kW
277°C
6.4 g/sec.
16 Pa
Wood
1.5 kg
3-7 kW
120 kg
135 mm
148 mm
Intermittent fuelling

Hide quick links: