  • Page 1 1001 1002 UK - ASSEMBLY AND INSTRUCTIONS MANUAL SCAN 1001 1002 ASSEMBLY AND INSTRUCTION MANUAL SCAN 1001/1002...
  • Page 2 1001 1002 CONGRATULATIONS ON YOUR NEW SCAN BUILT-IN STOVE You have purchased a product by one of Europe’s leading manufacturers of wood-burning stoves, and we are sure that you will have years of pleasure from your purchase. To make the best possible use of your stove, it is important that you follow our advice and instructions.
  • Page 3: Table Of Contents

    CONTENTS ¬ TECHNICAL DATA ¬ Installation Dimension sketch Scan 1001 Safety Dimension sketch Scan 1002 The Clean Air Act 1993 and Smoke Control Areas Type plate Technical data and dimensions Product registrationumber ¬ ASSEMBLY ¬ Tools needed for mounting of the insert...
  • Page 4: Technical Data

    Any changes made to the product by the dealer, fitter or user could result in the product and safety functions not functioning as intended. The same applies to the fitting of accessories or extra equipment not supplied by Scan A/S. This could also be the case if parts that are necessary for the operation and safety of the stove are dismantled or removed.
  • Page 5: Technical Data And Dimensions

    Required combustion air supply 19,8 Scan 1001-1002 is produced in accordance with type approv- Fuel Wood al for the product, which also covers the product’s Assembly and Instruction Manual.
  • Page 6: Dimension Sketch Scan 1001

    DIMENSION SKETCH SCAN 1001 Top outlet Rear outlet Centre external air supply, rear side Centre of external air supply, bottom All measures are in mm Scan 1001 Målskitse 91001001_stregtegning NAVN: EMNE: TG.NR:...
  • Page 7: Dimension Sketch Scan 1002

    DIMENSION SKETCH SCAN 1002 Top outlet Rear outlet Centre external air supply, rear side Centre of external air supply, bottom All measures are in mm...
  • Page 8: Type Plate

    PRODUCT REGISTRATIONUMBER All Scan built-in stoves are provided with a product registration number. Please make a note of this number at the rear page of this manual; you will always need to quote it when contacting your dealer or Scan A/S.
  • Page 9: Assembly

    Convection adaptors Ø149 mm (see page 20) ¬ Convection grates (See page 26) DISPOSAL OF PACKAGING Your Scan built-in stove may come supplied with the following packaging: The wood packaging can be reused and after final use can be incinerated as a CO neutral Wood packaging product or sent for recycling.
  • Page 10: Floor Plate

    EXISTING CHIMNEY AND PRE-FABRICATED ELEMENT CHIMNEY If you intend to connect your stove to an existing chimney, it makes sense to contact an authorised Scan dealer, or a local chim- ney sweep, for advice. These experts will also let you know if your chimney needs renovating.
  • Page 11: Trims And Doors

    Gasket DISTANCE TO FURNITURE Distance to furniture from glass: Scan 1001: 1300 mm. / Scan 1002: 1400 mm. You should however assess whether furniture or other items might become excessively dry due to being too close to the stove. The stove is NOT to be built into flammable materials without the use of a fire wall! SAFETY DISTANCE European, national and local regulations concerning safety distances for wood-burning stoves must be complied with.
  • Page 12: Building Into Flammable Material With Fire Wall

    02-05-12 MATERIALE: VÆGT: DATO: SIGN: Min. 500 cm DIMENSION: AREAL: Krog Iversen & Co A/S Upper DK-5492 Vissenbjerg© C:\Working Folder\Designs\Scan 1001\91001029.idw STI: convection opening Min. 350 cm Lower convection opening Distance to furniture from glass Floor Uisoleret røgrør Scan 1001...
  • Page 13 30 mm insulation all the way down to the insert Konstruktion/omramning mod loft Scan 1001 91001043 NAVN: EMNE: TG.NR: DATO: 21-06-2018 SIGN: MATERIALE: VÆGT: DIMENSION: AREAL: Krog Iversen & Co A/S DK-5492 Vissenbjerg© C:\Working Folder\Designs\Scan 1001\91001043.idw STI:...
  • Page 14 However, you should note that no top plate must be placed on the structure Scan 1001 Åben indbygning Scan 1001 91001050 TG.NR: NAVN: EMNE: 15-11-12 MATERIALE: VÆGT:...
  • Page 15: Operating The Door

    Check that the built-in stove is not damaged before installing it. Scan 1001/1002 is delivered secured to the pallet. It is recommended that you remove the door and take all loose parts out of the combustion chamber before unscrewing the stove from the pallet; this will facilitate the mounting of the insert.
  • Page 16 EMNE: TG.NR: the cassette to the pallet 17-04-12 TERIALE: VÆGT: DATO: SIGN: ENSION: AREAL: Krog Iversen & Co A/S DK-5492 Vissenbjerg© C:\Working Folder\Designs\Scan 1001\91001007.idw Afmontage ovn fra svøb Scan 1001 91001008 NAVN: EMNE: TG.NR: DATO: 17-04-2012 MATERIALE: VÆGT: SIGN: DIMENSION: AREAL: Krog Iversen &...
  • Page 17: Fitting The Flue Connection Piece

    Scan 1001 Montage røgstuds 91001025 NAVN: EMNE: TG.NR: DIMENSION: AREAL: 26-04-12 MATERIALE: VÆGT: DATO: SIGN: C:\Working Folder\Designs\Scan 1001\91001025.idw STI: DIMENSION: AREAL: Krog Iversen & Co A/S DK-5492 Vissenbjerg© C:\Working Folder\Designs\Scan 1001\91001025.idw STI: Montage røgstuds an 1001 EMNE: 91001025 TG.NR: 26-04-12 VÆGT:...
  • Page 18: Mounting Of External Air Supply

    24-04-12 ALE: VÆGT: DATO: SIGN: DIMENSION: AREAL: Krog Iversen & Co A/S DK-5492 Vissenbjerg© C:\Working Folder\Designs\Scan 1001\91001032.idw STI: ION: AREAL: Krog Iversen & Co A/S DK-5492 Vissenbjerg© \Working Folder\Designs\Scan 1001\91001020.idw Mount the Ø100 sleeve Ekstern forbrænding bag på svøb an 1001...
  • Page 19 NAVN: EMNE: TG.NR: 91001032 07-05-2012 MATERIALE: VÆGT: DATO: SIGN: DIMENSION: AREAL: Krog Iversen & Co A/S DK-5492 Vissenbjerg© C:\Working Folder\Designs\Scan 1001\91001032.idw STI: Mount the Ø100 sleeve Scan 1001 Frisklufttilførsel bund af ovn 91001032 NAVN: EMNE: TG.NR: 07-05-2012 MATERIALE: VÆGT: DATO:...
  • Page 20: Fitting Without The Convection Connection Pieces

    DIMENSION: AREAL: Krog Iversen & Co A/S DK-5492 Vissenbjerg© C:\Working Folder\Designs\Scan 1001\91001046.idw STI: FITTING THE CONVECTION CONNECTION PIECES (ACCESSORY) Convection connection pieces Ø149 mm To dismount the cover plates for the convection adaptors, use an slotted screwdriver as shown below. Tilt the screwdriver and loosen the cover plates.
  • Page 21: Fitting The Cassette

    TG.NR: 02-05-12 DATO: MATERIALE: VÆGT: SIGN DIMENSION: AREAL: Krog Iversen & Co A/ DK-5492 Vissenbjerg C:\Working Folder\Designs\Scan 1001\91001030.idw STI: Isætning cassette Scan 1001 EMNE: TG.NR: 91001014 To ensure that the cassette is level, you can adjust the 23-04-12 VÆGT: DATO:...
  • Page 22 NAVN: EMNE: MATERIALE: VÆG DIMENSION: AREAL: C:\Working Folder\Designs\Scan 1001\91001013.idw STI: Mount the rawl plugs, screws and discs. Make sure that the cassette is level before fastening it. In order to fasten the insert, you can use the delivered torx key that you will find...
  • Page 23 DATO MATERIALE: VÆGT: DIMENSION: AREAL: C:\Working Folder\Designs\Scan 1001\91001018.idw STI: Remove the top plate of the cassette The top plate of the cassette can be dismounted, after the cassette has been fastened. This can help facilitating the mounting of the insert...
  • Page 24: Mount The Insert In The Cassette

    91001027 AVN: EMNE: TG.NR: 26-04-2012 MATERIALE: VÆGT: DATO: SIGN: IMENSION: AREAL: Krog Iversen & Co A/S DK-5492 Vissenbjerg© C:\Working Folder\Designs\Scan 1001\91001027.idw Grip holes for pivot pins Styretapper og fanghuller Scan 1001 NAVN: EMNE: TG.NR: 91001017 24-04-12 MATERIALE: VÆGT: DATO: SIGN:...
  • Page 25: Mounting Of The Trim

    DIMENSION: AREAL: Krog Iversen & Co A/S DIMENSION: AREAL: Krog Iversen & Co A/S DK-5492 Vissenbjerg© C:\Working Folder\Designs\Scan 1001\91001031.idw STI: DK-5492 Vissenbjerg© C:\Working Folder\Designs\Scan 1001\91001031.idw STI: Remount the top plate of the cassette and the door MOUNTING OF THE TRIM We recommend that you do not mount the trim, until the insert has been approved by the chimney sweep, as he may demand to see the type plate which is situated on the top plate of the cassette (to dismount the top plate, see page 23).
  • Page 26: Indicator For Regulation Of Air Supply

    INDICATOR FOR REGULATION OF AIR SUPPLY The indicator for regulation of air supply is delivered separately. The indicator can be mounted on the trim as shown below. Scan 1001: 312 mm Scan 1002: 312 mm 387 mm Place the centre of the indicator...
  • Page 27: Mounting Of Convection Grate

    Indbygningsmål i mur Indbygningsmål i mur Indbygningsmål for konvektionsrist 91001053 EMNE: TG.NR: 1,64 kg 05-09-2017 VÆGT: DATO: SIGN: 279757 mm^2 AREAL: Krog Iversen & Co A/S DK-5492 Vissenbjerg© er\Designs\Scan 1001\91001053.idw...
  • Page 28: Mounting Of Combustion Chamber

    DIMENSION: AREAL: Krog Iversen & Co A/S DK-5492 Vissenbjerg© C:\Working Folder\Designs\Scan 1001\91001040.idw STI: Note that the baffle plates are made of porous, ceramic material, and can break. Exercise care when working Mount the left burn chamber plate Mount the rear plates.
  • Page 29 Place the log guard against the front of the insert Place the bottom stones with the inclined edge turning to the rear and downwards Nederste røgvenderplade Scan 1001 NAVN: EMNE: 15-0 MATERIALE: VÆGT: DATO: DIMENSION: AREAL: Krog Ive DK-549 C:\Working Folder\Designs\Scan 1001\91001041.idw STI:...
  • Page 30: Instructions For Use

    Adjustment of air supply, primary and secondary damper CB-technique Primary air Scan 1001 Tertiærkasse, luftindikator 91001021 NAVN: EMNE: TG.NR: 0%-100% 0%-100% 25-04-2012 MATERIALE: VÆGT: DATO: SIGN: Primary air Secondary air DIMENSION: AREAL: Krog Iversen & Co A/S DK-5492 Vissenbjerg© C:\Working Folder\Designs\Scan 1001\91001021.idw STI:...
  • Page 31: Instructions For Heating

    LIGHTING We recommend the use of fire lighters, or similar products, which are available from your Scan dealer. Using fire lighters helps light the wood more quickly and keeps the combustion process clean. See our video about correct firing on www.scan.dk or scan the QR-code.
  • Page 32: Continuous Operation

    CONTINUOUS OPERATION It is important to obtain as high a temperature as possible in the combustion chamber. This results in best possible use of the stove and fuel, as well as achieving clean combustion. In this way you will avoid build-up of soot on the combustion chamber lining and glass pane.
  • Page 33: Handling Of The Fuel

    HANDLING OF THE FUEL SELECTING WOOD/FUEL You can use any type of wood as fuel. However harder woods, such as beech or ash, are generally better for heating, as they burn more evenly and create less ash. Other woods, such as maple, birch and spruce, are excellent alternatives. PREPARATION The best fuel is obtained where the tree has been felled and the wood sawn and split before May 1st.
  • Page 34: Maintenance

    Clean your wood-burning stove by wiping it down with a dry, lint-free cloth. If the paint finish gets damaged, you can purchase repair paint in spray form from your Scan dealer. As slight differences in colour shade are possible, we recommend you spray a larger area to achieve a natural blend. For best results, apply repair spray when the stove is warm enough for you to just keep your hand on it, but no hotter.
  • Page 35: Cleaning The Glass

    DATO: SIGN: DIMENSION: AREAL: Krog Iversen & Co A/S DISPOSAL OF STOVE PARTS DK-5492 Vissenbjerg© C:\Working Folder\Designs\Scan 1001\91001012.idw STI: Steel/cast iron Send for recycling Glass Dispose of as ceramic waste Combustion chamber lining Vermiculite and chamotte are not recyclable. Dispose of as waste.
  • Page 36 TROUBLESHOOTING SMOKE ESCAPING ¬ Damp wood ¬ Chimney not drawing properly ¬ Chimney is not properly dimensioned for the built-in stove ¬ Check if the smoke gas pipe/chimney are blocked ¬ Is the chimney the right height for its surroundings? ¬...
  • Page 37 You must quote your stove‘s product registration number when you contact us or your authorised Scan dealer with a warranty claim. The warranty covers all parts which in the opinion of Scan A/S require repair or replacement due to manufacturing or construc- tion error The warranty applies to the original purchaser of the product only, and is not transferable (except on prior sale).
  • Page 38 Krog Iversen & Co A/S REFUELLING ON TO A LOW FIRE BED DK-5492 Vissenbjerg© C:\Working Folder\Designs\Scan 1001\91001048.idw STI: If there is insufficient burning material in the firebed to light a new fuel charge, excessive smoke emission can occur. Refuelling must be carried out onto a sufficient quantity of glowing embers and ash that the new fuel charge will ignite in a reasonable period.
  • Page 39 NOTES...
  • Page 40 Product registration number Quote this number at all enquiries Edition: UK 91001500 SCAN A/S Glasvænget 3-9 DK-5492 Vissenbjerg www.scan.dk 25.06.2018...