Download Print this page

Screen Adjustment - Da-Lite Tensioned Large Cosmopolitan Electrol Instruction Book

9'x12', 180" diagoanal and larger sizes
Hide thumbs Also See for Tensioned Large Cosmopolitan Electrol:

Advertisement

SCREEN ADjUSTMENT

screen travel is stopped automatically in the down and up positions by the limit switches that are preset at the factory.
no further adjustment is necessary.
s
!
CONTACT DA-LITE AT 800-622-3737 OR 574-267-8101 IF SCREEN MOTOR NEEDS ADjUSTMENT.
TENSIONED COSMOPOLITAN
CONTROL
Internal wiring has been completed at the factory. Installer must route power to the wall switch and to the junction box
located on the left end of the screen case.
see wiring diagram below for wire connections.
NOTE: This screen can only be controlled by a single 120VAC or 240VAC wall switch. To use multiple switches, an optional low
voltage control must be used.
120V WIRING DIAGRAM
FOR STANDARD
WALL SWITCH
JunCTIOn bOX
lOCaTEd In lEfT
EndCaP
sPdT sWITCh WITh
aC (COmmOn)
CEnTER Off
blaCk
uP
aC hOT 120vaC 60hZ 1 amP
Off
blaCk/YEllOW
REd
dOWn
nOTE: a sInglE sWITCh CannOT bE usEd TO OPERaTE mORE Than
OnE sCREEn. COnTaCT ThE faCTORY fOR fuRThER
ThIs sWITCh Can nOT
InfORmaTIOn.
bE usEd WITh lvC.
ELECTROL
INSTALLATION FOR SCREENS WITHOUT A BUILT-IN LOW VOLTAGE
®
®
WhITE
blaCk
mOTOR
REd
gREEn
240 VOLT WIRING DIAGRAM FOR
STANDARD WALL SWITCH:
da-lite offers two styles of 240 volt
wall switches for standard operation.
Please see wiring diagram in wall
switch boxes included with screen.
3

Advertisement