2HA/2HB

Periodic maintenance procedures

Maintenance
Section
part/location
Test copy
Perform at the maxi-
and test print
mum copy size
Maintenance
Section
part/location
Paper feed
Paper feed pulley
section
Separation pulley
Forwarding pulley
MP paper feed pulley
MP separation pad
Left registration roller
Right registration roller
Registration cleaner
Maintenance
Section
part/location
Optical
Slit glass
section
Contact glass
Mirror 1
Mirror 2 and mirror 3
Lens
Reflector
Exposure lamp
Optical rail
Original size detection
sensor
Laser scanner unit
Maintenance
Section
part/location
Transfer and
Transfer roller
separation
Separation electrode
section
2-4-6
Method
Maintenance cycle
Test copy
Every service
Method
Maintenance cycle
Check or replace -
Check or replace -
Check or replace -
Clean or replace Every 150,000 counts
Check or replace -
Clean or replace Every 150,000 counts
Clean
Every 150,000 counts
Clean or replace Every 150,000 counts
Method
Maintenance cycle
Clean
Every 150,000 counts
Clean
Every 150,000 counts
Clean
-
Clean
-
Clean
-
Clean
-
Check or replace -
Check or grease -
Check or clean -
Check or clean Every 150,000 counts
Method
Maintenance cycle
Clean
Every 150,000 counts
Check or clean -
Points and cautions
Points and cautions
Clean with the alcohol.
Clean with the alcohol.
Clean with the alcohol.
Clean with the alcohol.
Clean with the alcohol.
Clean with alcohol or a dry cloth.
Clean with alcohol or a dry cloth.
Vacuum.
Points and cautions
Clean with a dry cloth.
Clean with alcohol and then a
dry cloth.
Clean with a wet cloth and then
a dry cloth only if vertical black
lines appear on the copy image.
Clean with a wet cloth and then
a dry cloth only if vertical black
lines appear on the copy image.
Clean with a dry cloth only if
vertical black lines appear on
the copy image.
Clean with a dry cloth only if
vertical black lines appear on
the copy image.
Replace if an image problem
occurs or after the exposure
lamp does not turn on.
Check noise and shifting and
then apply scanner rail grease
EM-50L.
Clean with alcohol or a dry cloth.
Clean the slit glass with alcohol.
Points and cautions
Vacuum or clean with a dry cloth. P.1-5-27
Clean with the equipped brush.
Page
Page
P.1-5-5
P.1-5-3
P.1-5-5
P.1-5-9
P.1-5-9
P.1-5-11
P.1-5-11
Page
P.1-5-12
Page