INSTALLATION
THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER
Each Kit contains one LP
Conversion Kit # 576-972
Conversion Kit Contains:
Qty.
Part #
Description
1
904-645
Burner Orifi ce #51
1
904-529
5/32" Allen Key
1
918-590
Decal "Converted
to LPG"
1
908-528
Red "LP" label
1
910-037
LP Injector (Pilot
Orifi ce)
1
918-961
Instruction Sheet
Installation of LP
Conversion Kit:
1)
Shut off the gas and electrical supply.
Remove the louvers (and Arch screen
2)
doors if they are installed).
Open the fl ush door and remove the
3)
door.
Remove the logs and embers (if already
4)
installed).
Loosen the 2 screws holding the Burner
5)
Assembly to the fi rebox base. Slide the
Burner Assembly to the left to release it
from the orifi ce and lift out.
Remove the 2 screws, push Burner Assembly
to the left and lift out.
40
CONVERSION KIT #576-972 FROM NG TO LP
for B36XTCE using SIT 886 NOVA Gas Valve
IF IN DOUBT DO NOT DO THIS CONVERSION !!
Remove the pilot shield by removing 2
6)
screws.
Remove the wire clip below the pilot cap.
7)
Pull off the pilot cap to expose the pilot
8)
orifi ce.
Unscrew the pilot orifi ce with the allen
9)
key; then replace with the LPG pilot
orifi ce, provided in the kit.
10) Re-install pilot cap and pilot shield.
11) Remove burner orifi ce with a 1/2"
wrench. Use another wrench to hold on
to the elbow behind the orifi ce. Discard
orifi ce.
12) Reinstall new burner orifi ce LPG
stamped #51 and tighten.
13) Reinstall burner assembly.
14) Adjust aeration accordingly.- see
manual for details.