Venting Introduction; Vent Restrictor, Baffl E & Heat Defl Ector Installation - Regency bellavista B36XTCE Owner's Manual

Hide thumbs Also See for bellavista B36XTCE:
Table of Contents

Advertisement

VENT RESTRICTOR, BAFFLE & HEAT DEFLECTOR INSTALLATION
NOTE: THE VENT RESTRICTOR & BAFFLE MUST BE INSTALLED PRIOR TO OPTIONAL PANEL INSTALLATION.
1) Determine the venting confi guration.
2) Remove top heat defl ector and baffl e plate (reverse of steps 5 & 6).
3) Go to venting arrangements section (in the manual) to determine if
a vent restrictor setting is required.
Note: The vent restrictor does not apply to rear vent applications.
4) Align the vent restrictor plate to the required vent restrictor position
as per the Diagrams shown.
5) Once the vent restrictor plate is in the required position, secure with
2 - 1/4" x 1/2" screws. Ensure all screws are tight, but do not over
tighten. (See Diagram 2).
Regency B36XTCE Gas Fireplace
Diagram 2 Vent restrictor installed on top exhaust assembly
6) From inside the fi rebox, install the baffl e plate with 4 - 1/4" x 1/2 "
screws. Ensure all screws are tight, but do not over tighten.
Baffl e Plate
Note: If installing brick/optional panels, see brick/optional panel
instructions before proceeding to next step.
7) From inside the fi rebox, install the top heat defl ector with 2 -
1/4" x 1/2" screws. Ensure all screws are tight, but do not over
tighten.
Heat Defl ector
VENTING
INTRODUCTION
The B36XTCE uses the "balanced fl ue" technology Co-Axial system.
The inner liner vents products of combustion to the outside while the outer
liner draws outside combustion air into the combustion chamber thereby
eliminating the need to use heated room air for combustion and losing
warm room air up the chimney.
Note:
These fl ue pipes must not be connected to any other
appliance.
The gas appliance and vent system must be vented directly to the outside
of the building, and never be attached to a chimney serving a separate solid
fuel or gas burning appliance. Each direct vent gas appliance must use it's
own separate vent system. Common vent systems are prohibited.
INSTALLATION
Diagram 3
Diagram 4