Mantel Clearances - Regency bellavista B36XTCE Owner's Manual

Hide thumbs Also See for bellavista B36XTCE:
Table of Contents

Advertisement

Due to the extreme heat this fi replace emits, the mantel clearances are critical. Combustible mantel clearances from top of front facing are shown in
the Diagram on the right.
Note: A non-combustible mantel may be installed at a lower height if the framing is made of metal studs covered with a non-combustible board.
24
12
0
Inches

Mantel Clearances

B36XTCE
From Top of Fireplace
Opening
Note: Ensure the paint that is used on the mantel and the facing is "High Quality" or the paint may discolour.
Regency B36XTCE Gas Fireplace
MANTEL CLEARANCES
Mantel Clearances
14
12
10
8
6
12"
7"
B
C
A
To Floor
A
29-11/16"
(754mm)
4
2
Combustible
Non-combustible
1"
Header
(steel stud)
on edge
Non-combustible
D
3-1/2"
Standoff
Top of
Fireplace
Opening
B
C
23-1/2"
20"
(597mm)
(508mm)
INSTALLATION
D
15-1/2"
(394mm)
11

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents