14. PEPLACING THE POWER CORD
WARNING :
Personal Injury Hazard
Disconnect from the power supply before servicing the unit. Failure to do so could result in electric shock or
other personal injury.
CAUTION :
Personal Injury Heazard
Because of the weight and size of the microwave oven, two people are required to safely move and install it.
Failure to do so could result in personal injury.
1. Remove the microwave oven from its mounting location.
2. Remove the vent grille, the wire protector and the cabinet from the microwave oven (See Cabinet Removal, FIG.1).
Refer to FIG. 14 and the inset for the following steps.
3. Unplug the housing with black and white power cord leads.
4. Remove the ground screw from the green power cord lead.
5. Remove the old power cord.
6. Push the new power cord Strain relief black into the slot of the guide air top.
7. Connect the power cord lead to the terminals of the hoise filter.
8. Use the ground screw to secure the ground wire to the front plate.
9. Refer to Cabinet Installation and reinstall the cabinet and the vent grille on the microwave oven.
10. Reinstall the microwave oven in its mounting location.
FIG. 14
22