② Please select the mode you wish to operate by pressing the LEFT or RIGHT button.
- ATW(Auto Tracking White Balance) : This mode can be used within the color
temperature range 1,800°K ~ 10,500°K (eg, fluorescent light, outdoor, sodium
vapor lamp or inside tunnels)
- AWC(Auto White Balance Control) : Please press the SETUP button while
the camera is directed at a piece of white paper to obtain the optimum state
under current illumination. If the environment including the light source is
changed you have to adjust the white balance again.
- MANUAL : The manual adjustment mode enables finer adjustment.
Please select ATW or AWC first. Please change to manual adjustment mode
and press the SETUP button. Please set the appropriate color temperature,
and then increase or decrease the red and blue color values while monitoring
the color changes on the object.
Note)
• Under the following conditions the WHITE BALANCE function may not operate
properly. In such cases, please select the AWC mode.
When the object's surroundings have a very high color temperature
(eg, a clear sky and sunset)
When the object's surroundings are dark
If the camera directly faces a fluorescent light or is installed in a place where
there are considerable changes in illumination, the WHITE BALANCE function may
become unstable
5) BLAKLIGHT
When there is a strong backlight behind the object, clear images of the background as well
as the object can still be obtained by using the backlight function.
① Please position the arrow to point to 'BACKLIGHT' on the SETUP menu by using
the UP and DOWN buttons.
.
LENS
SHUTTER
WHITE BAL
►BACKLIGHT
AGC
DNR
SENS-UP
SPECIAL
EXIT
SETUP
MANUAL
ESC
ATW
OFF
LOW
LOW
OFF