HP ProLiant ML370 G5 User Manual page 47

Hp proliant ml370 generation 5 server user guide
Hide thumbs Also See for ProLiant ML370 G5:
Table of Contents

Advertisement

FBDIMM installation guidelines
Always observe the following guidelines when installing additional memory:
Always install memory in pairs of equal capacity.
Install FBDIMMs into both slots within a single bank.
Always install memory in pairs in sequential bank order, starting with bank A.
Install supported DDR2 FBDIMMs.
For maximum performance, install a minimum of four FBDIMMs across both memory boards (two
FBDIMMs per board).
For online spare and mirrored memory support, always observe additional guidelines
memory" on page 43).
Removing FBDIMMs
To remove the component:
Power down the server (on page 20).
1.
Do one of the following:
2.
Open or remove the tower bezel, as needed
Extend the server from the rack (on page 22).
Remove the access panel (on page 25).
3.
Remove the processor air baffle (on page 26).
4.
Remove a memory board
5.
Open the FBDIMM slot latches.
6.
Remove the FBDIMM.
7.
Install the memory board
8.
Install the processor air baffle.
9.
Install the access panel.
10.
Do one of the following:
11.
Close or install the tower bezel, as needed.
Slide the server back into the rack.
("Open or remove the tower
("Removing and installing a memory
("Removing and installing a memory
("Online spare
bezel" on page 21).
board" on page 45).
board" on page 45).
Hardware options installation 47

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents