HP Systems Insight
Display LED color
PPM failure, slot X
(amber)
DIMM failure, slot X
(amber)
DIMM bank error (all
slots in one bank,
amber)
DIMM failure (all
slots, amber)
Over temperature
alert (amber)
Fan (amber)

SAS and SATA device numbers

The server supports a combination of up to 16 SAS and SATA hard drives in two hard drive cages.
HP recommends populating hard drive bays starting with the lowest SAS or SATA device number.
Internal system
Status
health LED color
Amber
Processor in socket X is in a pre-failure condition.
Red
One or more of the following conditions may exist:
PPM in slot X has failed.
PPM is not installed in slot X, but the corresponding
processor is installed.
Red
One or more of the following conditions may exist:
DIMM in slot X has failed.
DIMM has experienced a multi-bit error.
Amber
One or more of the following conditions may exist:
DIMM in slot X has reached single-bit correctable
error threshold.
DIMM in slot X is in a pre-failure condition.
Red
One or more of the following conditions may exist:
The bank is not populated entirely.
All DIMMs in the bank do not match.
Red
One or more of the following conditions may exist:
No valid or usable memory is installed in the system.
The banks are not populated in the correct order.
Red
System temperature has exceeded OS cautionary level or
critical hardware level.
Red
A required fan has failed.
Amber
A redundant fan has failed.
Component identification 15