Dmx Operation - Martin Magnum Club Smoke System User's Manual And Installation Instructions

Magnum club smoke system
Table of Contents

Advertisement

MAGNUM CLUB SMOKE SYSTEM

DMX OPERATION

The system may be operated using the industry standard DMX 512 digital
control protocol. This allows the control of the fog system to be easily
integrated with the lighting system in most installations.
DMX may be used without disconnecting the remote control, although the
timer should be switched off to prevent the remote from overriding the DMX
level setting.
The system implements true proportional control of the fog output rather than
the simple switching functions found on other equipment.
See the system specifications for the DMX protocol, and the installation
instructions for the DMX channel settings.
The heaters in the Heads will switch on when the DMX receiver detects valid
data on the link; a channel other than 0 must be set on the address DIP
switches.
To switch off the heaters, simply switch off the DMX transmitter.
When operating from a traditional desk with faders, a 10% dead-band is
implemented at the low end of the output range. Within this range, the output
from the heads is zero.
The system uses a 'pump ramping' technique to allow continuous operation.
This means that transmitting DMX 100% will cause the machine to run at full
output until the temperature falls and the output is automatically reduced.
The output will remain at this level until the DMX signal is reduced, or the
fluid is exhausted. There is no possibility of damage, since the electronic
fluid level sensor will shut the system down.
6
USER
INSTALLATION
GUIDE
INSTRUCTIONS
SERVICE MODULE INSTALLATION
The service module is wall mountable via the mounting bracket provided,
although the unit can equally be used floor standing.
To fix the unit to the wall, remove the bracket from the unit and fix to the wall
using 2 x M6 Rawl bolts (or equivalent). Remember to allow enough
clearance above the unit for the cable connections.
If you want to be able to remove the side panels for service purposes, allow
15cm clear space to either side.
Once the bracket is fitted securely to the wall, the unit can be hooked on and
the retaining bolts (2 x M6) fitted.
The functions of the service module connectors are shown on the top panel,
and also in the specifications at the end of this guide.
Connect the control cables to the two heads into the female XLR3
connectors marked Ch1 and Ch2.
The remote control (if required) is connected into the male socket marked
REMOTE. The fluid lines are connected to the two 'push-in' connectors
marked Ch1 and Ch2.
DMX connections are made via the two XLR3 connectors marked DMX IN
and DMX OUT.
MAGNUM CLUB SMOKE SYSTEM
REMOTE
FLUID 2
FLUID 1
HEAD 1
HEAD 2
POWER
ON/OFF
11

Advertisement

Table of Contents
loading