System Expansion - Martin Magnum Club Smoke System User's Manual And Installation Instructions

Magnum club smoke system
Table of Contents

Advertisement

MAGNUM CLUB SMOKE SYSTEM
INTRODUCTION
The MAGNUM CLUB SMOKE is a system designed for fixed installations
and overcomes the problems associated with installing traditional fog
machines.
Separating the fluid from the vaporising unit allows the Head to be installed
in any location without the need to have access for fluid refills.
The fluid is contained in the wall mountable service module which can be
located away from the heads where access is easy.
The fluid level is monitored electronically and a fluid out indicator is visible at
the front of the service module. This prevents damage to the pumps
occurring due to lack of fluid.
The service module also contains the DMX decoder, allowing the address
setting to be changed without needing access to the heads.
Installation is simple and requires no special tools, since the fluid
connections are made using 'push-in' fittings and flexible nylon piping.
Once installed, the system can be operated from the remote control or a
standard DMX 512 compliant lighting console.
FEATURES
Standard system includes two
Heads
Wall mountable Service Module
Remote control included
0 - 10 V analogue control is possible
DMX decoder as standard
10m fluid lines and control cables
Service module can be located up
to 50m from Heads
2
USER
GUIDE
10L fluid container
Continuous operation from up to 4
Heads
Electronic fluid level sensing and
shutdown
System expansion to 4 Heads
Operation can be linked with JEM
AF1 fan unit
Fluid connections using 'Push-In'
fittings
MAGNUM CLUB SMOKE SYSTEM
INSTALLATION
INSTRUCTIONS

SYSTEM EXPANSION

The standard system can be expanded to operate 4 heads and the JEM AF-
1 fan unit.
The additional heads are standard units and require only two additional parts
to allow them to be integrated into the standard two head system. The
maximum separation between two heads connected in this way is 10m.
The control cable is extended using a standard XLR3 cable into the
analogue out of the existing head, and the fluid line is fitted with a 'T' adaptor
to provide fluid to the new head.
The AF-1 fan can be connected to the control cable by using the analogue
out of the last head to connect to the analogue in of the AF-1 fan.
EXISTING HEAD
'T' PIECE
FLUID LINE
CONTROL CABLE
TO SERVICE
MODULE
NEW HEAD
TO Af1
ANALOGUE IN
15