Specification - Martin Magnum Club Smoke System User's Manual And Installation Instructions

Magnum club smoke system
Table of Contents

Advertisement

MAGNUM CLUB SMOKE SYSTEM

SPECIFICATION

HEAD
1KW heater
Copper vaporizing coil
High pressure fluid delivery
Electronic Temperature control using thermocouple
Analogue remote control system
Solenoid operated flow control valve
Adjustable mounting bracket
Maximum distance to service module 50 m
Maximum height above service module 10m
SERVICE MODULE
Oscillating piston high pressure fluid pumps
Low fluid detection by electronic sensor
DMX512 decoder:
Required Channels = 1
Output is proportional for all levels above 10%
Channels supported = 1 to 512
Valid start codes = 0 (dimmer data only)
Full framing error detection implemented
Analogue control via standard Martin Multifunction Controller.
REMOTE CONTROL
16v power supply from service module
Standard 0 - 10V output signal
Output level control from 0 to 100%
Power On LED
Timer cycle LED
Timer range:
Delay time
2sec - 18 sec (x1)
Run time
2sec - 18 sec (x1)
16
16 sec - 2 min24sec(x8)
16 sec - 2 min24sec(x8)
MAGNUM CLUB SMOKE SYSTEM
USER GUIDE CONTENTS
Introduction
Features
Safety Guidelines
System Components
Remote Control Operation
DMX Operation
System Expansion Options
Fault Finding
INSTALLATION INSTRUCTIONS CONTENTS
System Layout Guidelines
Head Installation
Service Module Installation
DMX Settings
Commissioning The System
Maintenance
System Expansion
Specifications
©
2004
Martin Professional A/S, Denmark.
All rights reserved. No part of this manual may be reproduced, in any form or
by any means, without permission in writing from Martin Professional A/S,
Denmark.
1

Advertisement

Table of Contents
loading

Table of Contents