Sign In
Upload
Manuals
Brands
Toshiba Manuals
UPS
4200FA Series
Toshiba 4200FA Series Manuals
Manuals and User Guides for Toshiba 4200FA Series. We have
8
Toshiba 4200FA Series manuals available for free PDF download: Installation And Operation Manual, User Manual, Operation Manual, Installation Planning Manual, Specifications
Toshiba 4200FA Series Installation And Operation Manual (138 pages)
Three-Phase 15/25/30/50 kVA UPS
Brand:
Toshiba
| Category:
UPS
| Size: 5.16 MB
Table of Contents
Purpose and Scope of Manual
6
Table of Contents
7
List of Tables
10
1 General Safety Instructions
13
Equipment Warning Labels
14
Important Safety Instructions
17
Table 1.1 Recommended Over-Current Protection
17
2 Instructions Importantes Concernant la Sécurité
20
3 Product Description
21
Theory of Operation
21
Application and Use
21
Power Backup
21
Power Conditioning
21
4 Product Unpacking / Inspection / Storage / Disposal
23
Unpack the Premium 15/25/30 Kva UPS (with Casters)
23
Unpack the Base and Seismic Model 15/25/30 Kva UPS (Without Casters)
24
Unpack the Premium 50 Kva UPS (with Casters)
25
Unpack the Base and Seismic 50 Kva UPS (Without Casters)
26
Figure 4-1 Offload 50Kva UPS (no Casters)
26
Inspect UPS Equipment after Unpacking
27
Permanent Anchoring for Premium 15/25/30/50 Kva UPS (with Casters)
27
Figure 4-2 Anchoring for 15-30Kva with Casters
27
Permanent Anchoring for Base and Seismic Model 15/25/30/50 Kva UPS (Without Casters)
28
Figure 4-3 Anchoring for 50Kva with Casters
28
Figure 4-4 Anchoring Pattern for Basic and Seismic 50Kva (C-Channel Feet)
28
Storage of UPS Equipment
29
Disposal
29
5 Installation Precautions
30
Equipment Placement
30
System Preparation (Pre-Power)
31
Operating Precautions
31
6 UPS Connections
32
Power Connections
32
Power Connections 15/25/30 Kva with Internal Batteries
32
Power Connections 15/25/30 Kva with Internal Transformer
32
Figure 6-1 Power Cabling for 15-30Kva Units with Internal Batteries
32
Recommended Wire Size and Torque Requirements for 15/25/30Kva
33
Figure 6-2 Power Connections 15/25/30 Kva with Internal Transformer
33
Table 6.1 Cable Size for Different 3P-3W I/O Voltages
34
Table 6.2 Cable Size for 3P-4W I/O Voltages
34
Table 6.3 Cable Size for Ground
34
Table 6.4 Bypass Wire Size
35
Power Connection Cable Routing and Conduit Placement 15/25/30 Kva
36
Figure 6-3 15030Kva Cable Routing
36
Control Circuit and External Battery Interface Connections 15/25/30 Kva
37
Figure 6-4 15-30Kva Control and Battery Terminals -TB-3
37
Table 6.5 Remote Contacts Assignment
38
Recommended Wire Size and Torque Requirements
39
Power Connections - 50 Kva
39
Figure 6-5 Power Terminals - 50Kva
39
Table 6.6 UPS Control and Battery Wiring
39
Figure 6-6 Terminal Board Locations - 50Lva
40
Recommended Wire Size and Torque Requirements for 50Kva
41
Table 6.7 50Kva Cabling Sizes
41
Table 6.8 Bypass Cabling Sizes
41
Table 6.10 Grounding Cabling - 50Kva
42
Table 6.9 Battery Cabling - 50Kva
42
Figure 6-7 50Kva Cable Routing and Terminal Location
43
Power Cable Routing and Conduit Placement 50 Kva
43
Control Circuit and External Interface Connections 50 Kva
44
Figure 6-8 50Kva External Interface Assignments
44
Table 6.11 TB-3 Lug Assignment
45
Recommended Wire Size and Torque Requirements
46
Table 6.12 TB-3 Tightening Torque
46
Figure 6-9 DB-9 Pin Assignments
47
Remote Contact
47
Figure 6-10 Remoteye III and RS-232 Mounting Locations
48
Remoteye III
48
Rs-232C
48
Figure 6-11 RS-232C Pin Assignments
49
Table 6.13 Remoteye III Monitored Parameters
49
UPS Shutdown (Via RS-232C)
49
7 Specifications
50
4200FA 15 / 25 Kva @ 208 VAC Input/ 208 VAC Output - no Internal Batteries or Transformer
50
4200FA 15 / 25 Kva @ 208 VAC Input/ 208 VAC Output W/Internal Batteries
52
4200FA 15/25 Kva W/Internal Transformer
54
4200FA 30 Kva @ 208 VAC Input/ 208 VAC Output - no Internal Batteries, no Internal Transformer
56
4200FA 30 Kva @ 208 VAC Input/ 208 VAC Output W/Internal Batteries
58
4200FA 30 Kva W/Internal Transformer
60
4200FA 50Kva @ 208 VAC Input/ 208 VAC Output - no Internal Batteries, no Internal Transformer
62
4200FA 50Kva @ 208 VAC Input/ 208 VAC Output W/Internal Batteries
64
4200FA 50Kva W/Internal Transformer
66
4200FA Efficiencies and Thermal Losses at Various Loads
67
7.10.1 Efficiency with no Internal Transformers
67
Table 7.1 Thermal Loss in Btu/Hr. at Load (no Internal Transformers)
67
7.10.2 Efficiency with Input Transformer
68
7.10.3 Thermal Loss in Btu/Hr. with Input Transformer
68
7.10.4 Efficiency with Input and Output Transformer
68
7.10.5 Thermal Loss in Btu/Hr. with Input and Output Transformers
68
8 Operating the UPS
69
AC Input Mode (Normal Operation)
69
Figure 8-1 Power Flow in AC Input Mode
69
Bypass Mode
70
Figure 8-2 Power Flow in Bypass Mode
70
Bypass Mode for Optional Alternate Input Models
71
Figure 8-3 Power Flow in Bypass Mode for the Alternate Input Models
71
Battery Backup Mode
72
Figure 8-4 Power Flow in Battery Backup Mode
72
Battery Backup Time and Discharge Process
73
Battery Low Voltage Tolerances
73
Figure 8-5 Battery Discharge Curve
73
Battery Recharging
74
Figure 8-6 Battery Recharge Curve
74
9 Operator Interface
75
Front Panel Display Layout
75
Display Leds
75
Table 9.1 LED Behavior Key
75
Figure 9-1 Panel Layout for Touchscreen Display
75
Operator Manual Controls
76
Bypass/Online Switch
76
EPO (Emergency Power Off) Function
76
Figure 9-2 Effect of EPO Activation
76
Audible Alarm Functions
77
Display Reset Switch
77
Figure 9-3 Display Reset Switch
77
Table 9.2 AUDIBLE ALARMS
77
Figure 9-4 Touch Screen Layout
79
Table 9.3 Touch Screen Layout Components (Initial Main Display)
79
Touch Screen Display
79
Figure 9-5 Header Bar Detail
80
Figure 9-6 Footer Bar Detail
80
Footer Bar
80
Header Bar
80
Table 9.4 Header Bar Components
80
Table 9.5 Footer Bar Components
80
Figure 9-7 Monitor Display Layout
81
Table 9.6 Monitor Touch Screen Controls
81
Touch Screen Controls
81
Table 9.7 Quick Access Toolbar Controls
82
4200FA Touchscreen Menu Tree
83
Figure 9-8 Menu Tree
83
Figure 9-9 Changing Security Level
84
Toolbar: Buzzer ON/OFF
84
Toolbar: QUICK VIEW ON/OFF
84
Toolbar: Security
84
Toolbar: Touch ON/OFF
84
Figure 9-10 Quick View Display Layout
85
Table 9.8 Quick View Display Layout
85
Figure 9-11 MAIN Tab
86
MAIN Tab
86
Table 9.9 MAIN Tab Components
86
Figure 9-12 Monitor Tab Display Options
87
MONITOR Tab
87
Figure 9-13 MIMIC Display Current Flow Indicator
88
SETUP Tab
88
Figure 9-14 Setup Tab
89
Table 9.10 Setup Parameter Categories
89
Figure 9-15 Setup Keypad
90
Table 9.11 Touchscreen Kieypad Identification
90
Figure 9-16 Touch Screen Calibration
91
Setup: Calibrating the Touchscreen
91
Figure 9-17 RECORD Tab Layout
92
RECORD Tab
92
Table 9.12 RECORD Tab Description
92
Figure 9-18 Help Index
93
HELP Tab
93
System Fault Messages
93
Table 9.13 System Fault Messages
94
System Warning Messages
95
Table 9.14 System Warning Messages
95
System Mode Messages
96
System Status Messages
96
Table 9.15 System Mode Messages
96
Table 9.16 System Status Messages
96
10 UPS Operation
98
Initial UPS Startup
98
Starting the UPS
98
Stopping the UPS
99
EPO (Emergency Power Off) Function
99
Audible Alarm Functions
100
Table 10.1 AUDIBLE ALARMS
100
Initial Battery Charge
101
Start-Up Procedure
101
Shutdown Procedure
102
Maintenance Bypass Procedure
103
10.9.1 to Safely Set the Unit in Maintenance Bypass
103
10.9.2 Switch from UPS to Maintenance Bypass
103
10.9.3 Switch from Maintenance Bypass to UPS
104
Equalize Charge Mode Select
105
Overload Operation
105
11 UPS Protection System
105
System Protection Features
105
System Protection Functions
106
Table 11.1 Built-In UPS Fault Protection Functions
106
Figure 11-1 UPS Electrical Protection Sense Points
106
12 Start-Up / Scheduled Maintenance / Part Replacement
107
Start-Up
107
Preventive Maintenance
107
Table 11.2 Fault Alarms
107
Parts Replacement
108
13 External Dimensions / Shipping Dimensions / Weights
109
External Dimensions
109
Dimensions - 15/25/30 Kva with Casters
109
13.1.2 Dimensions - 15/25/30 Kva Without Casters
111
13.1.3 Dimensions - 50Kva with Casters
112
13.1.4 Dimensions - 50Kva Without Casters
113
Shipping Dimensions and Weights
114
Cabinet Color
114
Table 13.1 15-30Kva Shipping Dimensions
114
Table 13.2 50Kva Shipping Dimensions
114
Table 13.3 Weight of Premium and Seismic Units
114
Table 13.4 Weight of Base Units
114
APPENDIX A - Seismic Anchorages
115
APPENDIX B - Installation Planning Guides
119
APPENDIX C - 4200 FA Parameter Definitions
127
Advertisement
Toshiba 4200FA Series Installation And Operation Manual (98 pages)
Three-Phase 15/25/30/50 kVA UPS
Brand:
Toshiba
| Category:
UPS
| Size: 2.75 MB
Table of Contents
Important Notice
5
Purpose and Scope of Manual
6
Table of Contents
7
General Safety Instructions
11
Equipment Warning Labels
12
Important Safety Instructions
15
Instructions Importantes Concernant
18
1 Product Description
19
Theory of Operation
19
Application and Use
19
Power Backup
19
Power Conditioning
19
2 Product Unpacking / Inspection / Storage / Disposal
20
Unpack the Premium 15/25/30 Kva UPS (with Casters)
20
Unpack the Base and Seismic Model 15/25/30 Kva UPS (Without Casters)
21
Unpack the Premium 50 Kva UPS (with Casters)
22
Unpack the Base and Seismic 50 Kva UPS (Without Casters)
23
Inspect UPS Equipment after Unpacking
24
Permanent Anchoring for Premium 15/25/30/50 Kva UPS (with Casters)
24
Permanent Anchoring for Base and Seismic Model 15/25/30/50 Kva UPS (Without Casters)
25
Storage of UPS Equipment
26
Disposal
26
3 Installation Precautions
27
Equipment Placement
27
System Preparation (Pre-Power)
28
Operating Precautions
28
4 UPS Connections
29
Power Connections
29
Power Connections 15/25/30 Kva with Internal Batteries
29
Power Connections 15/25/30 Kva with Internal Transformer
30
Recommended Wire Size and Torque Requirements for 15/25/30Kva
31
Power Connection Cable Routing and Conduit Placement 15/25/30 Kva
32
Control Circuit and External Battery Interface Connections 15/25/30 Kva
33
Recommended Wire Size and Torque Requirements
34
Power Connections 50 Kva
35
Recommended Wire Size and Torque Requirements for 50Kva
36
Power Connection Cable Routing and Conduit Placement 50 Kva
37
Control Circuit and External Interface Connections 50 Kva
38
Recommended Wire Size and Torque Requirements
39
Communication Interface
40
Remote Contact
40
Rs-232C
41
UPS Shutdown (Via RS-232C)
42
5 Specifications
43
FA 15 / 25 Kva @ 208 VAC Input/ 208 VAC Output - no Internal Batteries or Transformer
43
4200FA 15 / 25 Kva @ 208 VAC Input/ 208 VAC Output W/Internal Batteries
44
4200FA 15/25 Kva W/Internal Transformer
45
4200FA 30 Kva @ 208 VAC Input/ 208 VAC Output - no Internal Batteries, no Internal
46
Transformer
46
4200FA 30 Kva @ 208 VAC Input/ 208 VAC Output W/Internal Batteries
47
4200FA 30 Kva W/Internal Transformer
48
4200FA 50Kva @ 208 VAC Input/ 208 VAC Output - no Internal Batteries, no Internal
49
Transformer
49
4200FA 50Kva @ 208 VAC Input/ 208 VAC Output W/Internal Batteries
50
4200FA 50Kva W/Internal Transformer
51
4200FA Efficiencies and Thermal Losses at Various Loads
52
6 Operating the UPS
53
AC Input Mode (Normal Operation)
53
Bypass Mode
54
Bypass Mode for Optional Alternate Input Models
54
Battery Backup Mode
55
Battery Backup Time and Discharge Process
56
Battery Low Voltage Tolerances
56
Battery Recharging
57
Front Panel Layout (All Units)
58
EPO (Emergency Power Off) Function
58
Audible Alarm Functions
59
LED (Light Emitting Diode) Functions
59
LED (Light Emitting Diode) System Status
60
LCD (Liquid Crystal Display) Functions
60
Line-1 System Messages
60
Line-2 System Fault Messages
61
Line-3 System Messages
61
Line-4 System Messages
61
Menu Tree
62
Initial Battery Charge
62
Start-Up Procedure
63
Shutdown Procedure
64
Maintenance Bypass Procedure
65
Switch from UPS to Maintenance Bypass
65
Switch from Maintenance Bypass to UPS
65
Keypad Overview
67
Key Functions
68
Moni
68
Out
68
BATT Key
69
MENU, F1, ENTER, UP, & down Keys
69
BATT TEST Key
69
BUZZ STOP Key
70
RESET Key
70
Menu Data Screens
71
Settings for Calendar and Clock
71
Adjusting the Buzzer Volume
71
Settings for Display Duration
71
Run Switch Select
72
Serial Com Station Address
72
Output Voltage Adjustment
73
Equalize Charge Mode Select
73
Reset to Default Settings
74
Overload Operation
74
Backup History and Fault History
75
7 UPS Protection System
77
System Protection Features
77
System Protection Functions
77
8 Start-Up / Scheduled Maintenance / Part Replacement
78
Start-Up
78
Preventive Maintenance
78
Parts Replacement
79
9 External Dimensions / Shipping Dimensions / Weights
80
External Dimensions - 15/25/30 Kva with Casters
80
External Dimensions - 15/25/30 Kva Without Casters
81
External Dimensions - 50Kva with Casters
82
External Dimensions - 50Kva Without Casters
83
Dimensions and Weights
84
Cabinet Color
84
APPENDIX A - Seismic Anchorages
85
APPENDIX B - Installation Planning Guides
89
Toshiba 4200FA Series User Manual (66 pages)
UNINTERRUPTIBLE POWER SYSTEM THREE-PHASE 15/ 25/ 30/ 33/ 50 kVA UPS
Brand:
Toshiba
| Category:
UPS
| Size: 1.21 MB
Table of Contents
General Safety Instructions
5
Signal Words
5
Special Symbols
6
Equipment Warning Labels
7
Table of Contents
9
Important Safety Instructions
11
Save These Instructions
11
1 Product Description
14
Theory of Operation
14
Application and Use
14
Power Backup
14
Power Conditioning
14
2 Uncrating/Inspection/Storage/Disposal
15
Uncrating the New UPS Equipment 15/25/30/33Kva
15
Uncrating the New UPS Equipment 50Kva
16
Inspection of the New UPS Equipment
16
Inspection of the New UPS Equipment
17
Storage of UPS Equipment
17
Disposal
17
3 Installation Precautions
18
Equipment Placement
18
System Preparation (Pre-Power)
19
Operating Precautions
19
4 UPS Connections
20
Power Connections 15/25/30/33 Kva with Internal Batteries
20
Power Connections 15/25/30/33Kva with Internal Transformer
20
Power Connections 15/25/30/33Kva with Internal Transformer
21
Recommended Wire Size and Torque Requirements
22
Power Connection Cable Routing and Conduit Placement
23
Control Circuit and External Battery Interface Connections 15/25/30/33 Kva
24
Recommended Wire Size and Torque Requirements
24
Power Connections 50 Kva
25
Recommended Wire Size and Torque Requirements for UPS Input and Output Terminals
26
Power Connection Cable Routing
27
Control Circuit and External Interface Connections
28
Recommended Wire Size and Torque Requirements
28
Communication Interface
29
Remote Contact
29
Rs-232C
30
UPS Shutdown (Via RS-232C)
30
5 Technical Data
31
4200FA 15 / 25Kva @ 208 VAC Input/ 208 VAC Output W/Internal Batteries
31
4200FA 15/ 25Kva W/Internal Transformer
32
4200FA 30 / 33Kva @ 208 VAC Input/ 208 VAC Output W/Internal Batteries
33
4200FA 30/ 33Kva W/Internal Transformer
34
4200FA 50Kva @ 208 VAC Input/ 208 VAC Output W/Internal Batteries
35
4200FA 50Kva W/Internal Transformer
36
Operating the UPS
37
AC Input Mode (Normal Operation)
37
Bypass Mode
37
Battery Backup Mode
38
Battery Backup Time and Discharge Process
39
Battery Low Voltage Tolerances
39
Battery Recharging
40
Front Panel Layout (All Units)
41
EPO (Emergency Power Off) Function
41
Audible Alarm Functions
41
LED (Light Emitting Diode) Functions
43
LED (Light Emitting Diode) System Status
43
LCD (Liquid Crystal Display) Functions
44
Line-1 System Messages
44
Line-2 System Fault Messages
44
Line-3 System Messages
44
Line-4 System Messages
45
Initial Battery Charge
46
Start-Up Procedure
47
Shutdown Procedure
48
Maintenance Bypass Procedure
49
Keypad Overview
50
Key Functions
51
Moni
51
Out
51
BATT Key
52
MENU, F1, ENTER, UP, & down Keys
52
BATT TEST Key
52
BUZZ STOP Key
53
RESET Key
53
Menu Data Screens
54
Settings for Calendar and Clock
54
Adjusting the Buzzer Volume
54
Settings for Display Duration
54
Run Switch Select
55
Serial Com Station Address
55
Output Voltage Adjustment
56
Charge Mode Select
56
Reset to Default Settings
57
Overload Operation
57
Backup History and Fault History
58
6 UPS Protection System
60
System Protection Features
60
System Protection Functions
60
7 Authorized Factory Service
61
Start-Up
61
Preventive Maintenance
61
Parts Replacement
62
8 External Layouts / Dimensions / Weights
63
External Dimensions 15/25/30/33Kva
63
External Dimensions 50Kva
64
Shipping Dimensions and Weights
65
Advertisement
Toshiba 4200FA Series User Manual (66 pages)
UNINTERRUPTIBLE POWER SYSTEM THREE-PHASE 80 kVA UPS
Brand:
Toshiba
| Category:
UPS
| Size: 1.75 MB
Table of Contents
Important Notice
5
Purpose and Scope of Manual
6
Table of Contents
7
General Safety Instructions
9
Equipment Warning Labels
10
Important Safety Instructions
13
Instructions Importantes Concernant
15
1 Product Description
16
Theory of Operation
16
Application and Use
16
Power Backup
16
Power Conditioning
16
2 Unpacking/Inspection/Storage/Disposal
17
Unpacking the UPS Equipment
17
UPS Equipment Inspection
18
Storage of the UPS Equipment
18
Disposal
18
3 Precautions
19
Installation Precautions
19
Pre-Start Precautions
20
Operating Precautions
20
4 UPS Connections
21
UPS Power and Control Connections
21
Recommended Wire Size and Tightening Torque for UPS Input/Output Terminals
22
Power Connection Cable Routing
23
Dual Input Configuration
31
Control Circuit and External Battery Interface Connections
32
Recommended Wire Size and Tightening Torque UPS Control and Battery Interface
32
Communication Interface
33
Remote Contact
33
Rs-232C
34
UPS Shutdown (Via RS-232C)
34
5 Specifications
35
Specifications - 4200FA 80Kva Without Internal Transformer
35
Specifications - 4200FA 80Kva with Internal Transformer
36
6 Operating the UPS
37
AC Input Mode (Normal Operation)
37
Bypass Mode
37
Battery Backup Mode
38
External Maintenance Bypass (Customer Supplied)
38
Battery Backup Time and Discharge Process
39
Battery Low Voltage Tolerances
39
Battery Recharging
40
Front Panel Layout (All Units)
41
EPO (Emergency Power Off) Function
42
Audible Alarm Functions
42
User Notification Leds
43
LED System Status
43
LCD Functions
44
Line-1 System Messages
44
Line-2 System Fault Messages
44
Line-3 System Messages
44
Line-4 System Messages
45
Initial Battery Charge
46
Start-Up Procedure
47
Shutdown Procedure
48
Keypad Overview
49
Key Functions
50
Moni
50
Out
50
BATT Key
51
MENU, F1, ENTER, UP/DOWN Keys
51
BATT TEST Key
51
BUZZ STOP Key
52
RESET Key
52
Menu Data Screens
53
Settings for Calendar and Clock
53
Adjusting Buzzer Volume
53
Settings for Display Duration
54
Run Switch Select
54
Serial Com Station Address
55
Output Voltage Adjustment
55
Equalize Charge Mode Select
56
Reset to Default Settings
56
Overload Operation
57
Backup History & Fault History
58
7 UPS Protection System
60
System Protection Features
60
System Protection Functions
60
8 Preventive and Scheduled Maintenance / Part Replacement
61
Preventive Maintenance
61
Parts Replacement
61
9 External Dimensions / Shipping Weights
62
External Dimensions
62
Shipping Dimensions
63
Shipping Weights
63
TOSHIBA 4200FA Series User Manual (65 pages)
UNINTERRUPTIBLE POWER SYSTEM THREE-PHASE 75 / 80 kVA UPS
Brand:
TOSHIBA
| Category:
UPS
| Size: 1.44 MB
Table of Contents
Important Notice
4
Table of Contents
5
Purpose and Scope of Manual
7
Contacting Toshiba's Customer Support Center
7
General Safety Instructions
8
Equipment Warning Labels
10
Important Safety Instructions
12
Instructions Importantes Concernant
14
1 Product Description
15
Theory of Operation
15
Application and Use
15
Power Backup
15
Power Conditioning
15
2 Unpacking/Inspection/Storage/Disposal
16
Unpacking the New UPS Equipment
16
Inspection of the New UPS Equipment
17
Storage of UPS Equipment
17
Disposal
17
3 Precautions
18
Installation Precautions
18
Pre-Start Precautions
19
Operating Precautions
19
4 UPS Connections
20
UPS Power and Control Connections
20
Recommended Wire Size and Tightening Torque for UPS Input and Output Terminals
21
Power Connection Cable Routing
22
Dual Input Configuration
30
Control Circuit and External Battery Interface Connections
31
Recommended Wire Size and Tightening Torque UPS Control and Battery Interface
31
Communication Interface
32
Remote Contact
32
Rs-232C
33
UPS Shutdown (Via RS-232C)
33
5 Specifications
34
Specifications - 4200FA 75Kva with Internal Transformer
34
Specifications - 4200FA 75Kva Without Internal Transformer
35
Specifications - 4200FA 80Kva with Internal Transformer
36
Specifications - 4200FA 80Kva Without Internal Transformer
37
6 Operating the UPS
38
AC Input Mode (Normal Operation)
38
Circuit-Bypass Mode
38
Battery Backup Mode
39
Battery Backup Time and Discharge Process
40
Battery Low Voltage Tolerances
40
Battery Recharging
41
Front Panel Layout (All Units)
42
EPO (Emergency Power Off) Function
43
Audible Alarm Functions
43
Light Emitting Diode (LED) Functions
44
Light Emitting Diode (LED) System Status
44
Liquid Crystal Display (LCD) Functions
45
Line-1 System Messages
45
Line-2 System Fault Messages
45
Line-3 System Messages
45
Line-4 System Messages
46
Initial Battery Charge
47
Start-Up Procedure
48
Shutdown Procedure
49
Keypad Overview
50
Key Functions
51
Moni
51
Out
51
BATT Key
52
MENU, F1, ENTER, UP/DOWN Keys
52
BATT TEST Key
52
BUZZ STOP Key
53
RESET Key
53
Menu Data Screens
54
Settings for Calendar and Clock
54
Adjusting Buzzer Volume
54
Settings for Display Duration
55
Run Switch Select
55
Serial Com Station Address
56
Output Voltage Adjustment
56
Charge Mode Select
57
Reset to Default Settings
57
Overload Operation
58
Backup History & Fault History
59
7 UPS Protection System
61
System Protection Features
61
System Protection Functions
61
8 Preventive and Scheduled Maintenance / Part Replacement
62
Preventive Maintenance
62
Parts Replacement
62
9 External Dimensions / Shipping Weights
63
External Dimensions
63
Shipping Dimensions
64
Shipping Weights
64
Toshiba 4200FA Series Operation Manual (20 pages)
BATTERY CABINET SYSTEM FOR 4200FA SERIES 15 & 25kVA UPS
Brand:
Toshiba
| Category:
UPS
| Size: 0.38 MB
Table of Contents
Important Notice
4
General Safety Instructions
5
Table of Contents
6
Contents
6
Important Safety Instructions
7
2 Uncrating/Inspection/Storage/Disposal
10
Uncrating the Battery System
10
Inspection of the New Battery System
11
Storage of the Battery System
11
Disposal
11
3 Installation
12
Installation Precautions
12
Conductor Routing and Grounding
12
4 Precautions
13
Prestart Precautions
13
Operating Precautions
13
5 Battery System Connections
14
Power Connections
14
Terminal Block Details
14
Wire Size and Tightening Torque
15
6 Specifications
15
7 Preventive Maintenance and Scheduled Maintenance/Parts Replacement
16
Preventive Maintenance
16
8 External Layouts/Dimensions/Weights
17
External Layouts: T42-BC-FA
17
External Dimensions
18
Toshiba 4200FA Series Installation Planning Manual (2 pages)
Toshiba Power Supply - UPS User Manual
Brand:
Toshiba
| Category:
UPS
| Size: 0.03 MB
Toshiba 4200FA Series Specifications (2 pages)
15/25/30/50/80 kVA UPS
Brand:
Toshiba
| Category:
UPS
| Size: 0.49 MB
Advertisement
Related Products
Toshiba 4200FA XT
Toshiba 4200FA CT/XT
Toshiba 4200 FA CT
Toshiba 4200FA CT
Toshiba 4200 series
Toshiba 431B
Toshiba 431M
Toshiba 431A
Toshiba 4400 Series
Toshiba 4310F3F300
Toshiba Categories
Laptop
Air Conditioner
TV
LCD TV
All in One Printer
More Toshiba Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL