Testing Procedures
!
WARNING
Gas Thermostat
This system uses a thermostat which internally selects
the Bake, Broil, and Clean circuits eliminating the
separate selector switch.
Verify voltage being supplied to the gas thermostat by
measuring voltage at terminal 2 of the gas thermostat,
meter should indicate 120 VAC.
Verify gas thermostat is working correctly by measuring
voltage at BA in bake mode, BR in broil mode, and C in
clean mode. All terminal points should indicate 120 VAC.
Dial
1-2
Main
COM-NO
Low Stop
N.S.
O
Bake
Cycles
N.S.
Broil
Cycles
N.S
Clean
Cycles
X Below
700° F
NOTE: When switching oven thermostat from broil to
bake always turn fully to OFF first. Otherwise
the broil burner remains on by the thermostat.

Oven Temperature Sensor

The oven temperature sensor can be checked by using
the "Quick Test Mode" covered in this section of manual
or detail testing can be accomplished as follows.
The oven temperature sensor is mounted in the oven
cavity and electrically connected to the ERC. Following
is approximate resistance.
75°F
350°F —
550°F —
880°F —
Sensor resistance can be checked by removing the
sensor interconnect harness plug from the ERC and
inserting ohmmeter leads into the harness connector
plug. A resistance reading of approximately 1100 ohms
should be indicated at ambient room temperature
(75°F.). If a higher resistance is indicated then remove
sensor from oven, disconnect sensor from harness at
plug, and recheck sensor resistance to assure that the
problem is in the sensor and not in the interconnect
harness or due to a bad connection.
RS2310002 Rev. 1
Contacts
COM-NC
C-BR
C-BA
X
O
O
N.S.
O
X
N.S.
X
O
X Above
O
O
700° F
1
2
C
7
COM
NC
NO
BR
BA
9
1082 ohms
1656 ohms
2056 ohms
2686 ohms
T T T T T o a
o a
o a
o a
o av v v v v oid the risk of electric shoc
oid the risk of electric shoc
oid the risk of electric shock, k, k, k, k, per
oid the risk of electric shoc
oid the risk of electric shoc
death, disconnect power before servicing, unless testing
death, disconnect power before servicing, unless testing
death, disconnect power before servicing, unless testing
death, disconnect power before servicing, unless testing
death, disconnect power before servicing, unless testing
requires it.
requires it.
requires it.
requires it.
requires it.
NOTE: Sensor resistance will increase if held in your
hand.

Cooling Fan Motor

Fan may come on at any time to cool components
down.
1. Turn off power to oven.
7-9
2. Disconnect wires from motor terminal connectors.
O
3. Attach ohmmeter leads to terminal tabs on motor.
O
4. A resistance reading of 15-30 ohms should be
O
X
indicated but may vary with each motor tested. This
test is to check the motor winding for an open or
shorted winding. If zero or infinite ohms is indicated,
the motor winding has failed and the motor must be
replaced.

Clean Circuit Manual Latch Switch

The latch switch is a single pole, single throw switch.
When the door latch is moved to the far right or locked
position, the switch contacts COM-NO provide a
connection path from gas thermostat to the clock timer,
terminal AT3.
The switch contacts can be checked as follows:
1. Turn off power to range.
2. Disconnect the switch wire leads and check the
COM-NO and COM-NC contacts for continuity.
3. When the door latch is in the left or unlocked
position, the COM-NO contacts should be open and
the COM-NC contacts should be closed.
4. Move the door latch to the far right or locked position.
The COM-NO contacts should be closed and the
COM-NC contacts should be open.