Fn=4: Function 4 Sending The Set Memory Switch Value - Citizen CT-S280 Command Reference Manual

Hide thumbs Also See for CT-S280:
Table of Contents

Advertisement

fn=4: Function 4 Sending the Set Memory Switch Value

GS ( E pL pH fn a
[Code]
<1D>H<28>H<45>H<pL><pH><fn><a>
[Range]
(pL+pH×256)=2
fn=4
CT-S280/BD2-2220
a=1, 2, 3
CT-S300
a=1, 2, 3, 4
CT-S281
CT-P29x series
a=1, 2, 3, 4, 5
CT-S801/CT-S851/CT-S601/CT-S601/CT-S310II
a=1, 2, 3, 4, 5, 6
PMU2300III
a=1, 2, 3, 4, 5, 11, 12
[Outline]
[The specification which is common to the model]
• Sends the content of MSW set in "a".
• Sends the set value of data in 8-byte data raw in order of bits 8, 7, 6
OFF: 30H ("0")
ON : 31H ("1")
[Caution]
[The specification which depend on the model]
CT-S310/CT-S2000/CT-S4000/
• MSW7 to MSW10 cannot be sent by this command.
• Transmission is available by <Sending preset customize value>.
CT-S310
CT-S2000
/
/
Hex.
Header
37H
ID
21H
Data
30H or 31H
NULL
00H
CT-S4000
PMU2XXX
/
/
No. of Data
1
1
8
1
CT-S801/CT-S601
- 220 -
PMU2XXXII
/

Hide quick links:

Advertisement

Table of Contents
loading