Printer Function Setting Commands - Citizen CT-S280 Command Reference Manual

Hide thumbs Also See for CT-S280:
Table of Contents

Advertisement

2.2.16 Printer Function Setting Commands

GS ( D pL pH m [a1 b1] ... [ak bk]
Support model
[Function]
Enabling or disabling real-time command
[Code]
<1D>H<28>H<44>H<pL>< pH>< m> [<a1>< b1>] ... [<ak>< bk>]
[Range]
3≤(pL+pH×256)≤65535
M=20
a=1
b=0, 1, 48, 49
[Outline]
[The specification which is common to the model]
• Enables/disables the following real-time command processing.
• pL and pH sets the number of bytes on and after m in (pL + pH×256).
• "a" sets the kind of real-time command.
• "b" sets Valid or Invalid.
• When data raw that meets the code configuring real-time command in the image data, it is recommended
that the real-time command be set to invalid by this command.
[Default]
[Caution]
[The specification which is common to the model]
PMU2XXXII/PMU2300III
Among PMU series, only PMU2xxxx type II and III support this function.
CT-S280
CT-S300
CT-S310
CT-S281
a
b
0, 48
Does not process DLE DC4 fn m t (fn=1). (Invalid)
1
1, 49
Processes DLE DC4 fn m t (fn=1). (Valid)
a
Type of Real-time Command
1
DLE DC4 fn m t (fn=1): Real-time output of pulse specified
CT-S2000
CT-S4000
CT-S801/851
CT-S601/651
Function
- 192 -
BD2-2220
PMU series
CT-P29x series
CT-S310 II
Initial Value
Valid

Hide quick links: