C
Specifications
GENERAL– Continued
Electrical
Specifications:
(Power)
Battery Pack Life:
RF SYSTEM PARAMETERS:
Frequency Band:
Channel Spacing:
Total Channel
Capability:
Duplex Method:
Transmitter
Output Power:
Receiver
Sensitivity:
OTHER:
Electrical
Requirements:
Requirements For
Out-Of-Building
Extensions:
Wiring:
146 Issue 3 October 1999
Handset
Battery Charger (BC)
Radio Module (RM)
Carrier (CA) w/6 RMs
Power Supply (BC)
Power Supply (RM)
Power Supply (CA)
Standard Nickel Metal Hydride
Extended Nickel Metal Hydride
902 – 928 MHz
150 KHz
50 (Channels Dynamically Allocated out of 173)
Time Division Duplex (TDD) (Transmit and Receive on same frequency)
Dynamic Power Adjustment: 1 mW ERP Minimum to 160 mW ERP Maximum
-103 dBm at Antenna Port
105–130VAC, 50–60 Hz, 3-prong outlet separate ground, separately at 15 amps
Outlet must not be controlled by an on/off switch
Grounding to comply with Underwriters Laboratories (UL) 1459
Installation of a telephone or other standard (tip/ring) device in another building requires
the following In-Range Out-of-Building (IROB) to protect the switch/control unit and
telephone device from surges:
MDW 9031/9031DCP Pocket Phone: two Lucent Technologies 146D protectors
(ETR); two Lucent Technologies 146E protectors (ATL)
MDW 9031/9031DCP Pocket Phone: Lucent Technologies SYSTIMAX
2-pair (4-wire) star ("home run" not "loop") ETR
Lucent Technologies SYSTIMAX or at least 4-pair (8-wire) star ("homerun" not
"loop") ATL
Bridging Adapter: Lucent Technologies 267F2 (ETR)
Bridging Adapter: Lucent Technologies 267C (ATL)
Range: 1,000 feet (305 m) for the Radio Module (26 AWG)
MDW 9031/9031DCP Wireless Pocket Phone Installation and Use 503-801-166
1.0 watt
15 watts
4.0 watts
24 watts
15 watts (10V 1.5 A)
6.0 watts (10V 600 mA)
30 watts (9V)
3 hours talk time/22 hours standby time
8 hours talk time/72 hours standby time
®
or at least