Olivetti d-Copia 600 Service Manual page 304

Color printer
Hide thumbs Also See for d-Copia 600:
Table of Contents

Advertisement

5. Remove the right roller of the cleaning felt
from the upper fuser frame pushing the
roller on machine front.
6. Remove the left roller of the cleaning felt
from the upper fuser frame pushing the
roller on machine front.
7. Replace the cleaning felt and attach the felt
to the upper fuser frame.
8. Refit the fuser cleaning cover to the upper
fuser frame.
9. Refit the upper fuser frame and upper fuser
cover to the fuser unit.
10. Refit the fuser unit.
11. Run maintenance item U909 (Checking/
clearing the fuser web count) to clear the
count (see page 1-4-70).
1-6-74
Left roller of
the cleaning felt
Service Manual
Right roller of
the cleaning felt
Figure 1-6-143
Upper fuser frame
Cleaning felt
Y104350-7