Olivetti d-Copia 600 Service Manual page 134

Color printer
Hide thumbs Also See for d-Copia 600:
Table of Contents

Advertisement

Maintenance
item No.
Setting the ejection restriction
U342
Description
Sets or cancels the restriction on the number of sheets to be ejected continuously when the internal eject tray
is selected as the eject location.
Purpose
According to user request, sets or cancels restriction on the number of sheets.
Method
1. Press the start key. The screen for selecting an item is displayed.
2. Select ON or OFF.
Display
ON
OFF
Initial setting: ON
3. Press the start key. The setting is set.
Completion
To exit this maintenance item without changing the current setting, press the stop/clear key.
The screen for selecting a maintenance item No. is displayed.
Switching between duplex/simplex copy mode
U343
Description
Switches the initial setting between duplex and simplex copy.
Purpose
To be set according to frequency of use: set to the more frequently used mode.
Setting
1. Press the start key. The screen for selecting an item is displayed.
2. Select ON or OFF. The selected item is displayed in reverse.
Display
ON
OFF
Initial setting: OFF
3. Press the start key. The setting is set, and the screen for selecting a maintenance item No. is displayed.
Completion
To exit this maintenance item without changing the current setting, press the stop/clear key.
The screen for selecting a maintenance item No. is displayed.
Setting the low-power mode
U344
Description
Changes the control for low-power mode.
Purpose
According to user request, selects which has priority, the recovery time from low-power or energy saver.
Method
Press the start key. The screen for selecting an item is displayed.
Setting
1. Select control mode. The selected item is displayed in reverse.
Display
ENERGY STAR
GEEA
Initial setting: ENERGY STAR (120 V specifications)/GEEA (220-240 V specifications)
2. Press the start key. The setting is set, and the screen for selecting a maintenance item No. is displayed.
Completion
Press the stop/clear key at the screen for selecting an item.
The screen for selecting a maintenance item No. is displayed.
1-4-62
Description
Description
Sets restriction on the number of sheets
Cancels restriction on the number of sheets
Description
Duplex copy
Simplex copy
Description
The fuser control temperature is lowered by 20
stabilization is performed 30 seconds after exiting preheat.
The fuser control temperature is lowered by 15
stabilization is performed 30 seconds after exiting preheat.
Service Manual
°
°
C/68
F and forced
°
°
C/59
F and forced
Y104350-7