(7) Adjusting magnification of the scanner in the main scanning direction
Perform the following adjustment if the magnification in the main scanning direction is not correct.
.
U065
(P. 1-6-54)
<Caution>
Check the copy image after the adjustment. If the image is still incorrect, perform the above adjustments in maintenance
mode.
<Procedure>
Start
Enter maintenance mode.
Enter 065 using the numeric keys.
Press the start key.
Select MAIN SCAN ADJ
(main scanning direction).
Press the interrupt key.
Place an original and press
the start key to make a test copy.
Is the image correct?
Press the stop/clear key.
Exit maintenance mode.
End
Y104350-7
U066
U070
(P. 1-6-91)
No
Yes
U403
(P. 1-6-55)
Original
Press the start key.
The new setting
is stored.
For copy example 1, increase the
value using the cursor up key.
For copy example 2, decrease the
value using the cursor down key.
Setting range: -25 to +25
Initial setting: 0
Changing the value by 1 changes
the magnification by 0.1%.
Increasing the value makes
the image wider, and decreasing it
makes the image narrower.
Sevice Manual
Copy
Copy
example 2
example
Figure 1-6-99
1-6-51