Table 1.35 [System Power Control] Window Button - Fujitsu PRIMEQUEST 2000 Series Tool Reference

Hide thumbs Also See for PRIMEQUEST 2000 Series:
Table of Contents

Advertisement

MMB Web-UI (Web User Interface) Operations
1.2 [System] Menu for PRIMEQUEST 2400E2/2800E2/2400E/2800E

TABLE 1.35 [System Power Control] Window Button

Buttons
Apply
When the [Apply] button is clicked after selecting the control item by the radio button, the power
supply is controlled according to the selected information.
Cancel
When the [Cancel] button is clicked, the power supply returns to the original state without being
controlled.
(1)
Menu Operation
[System] – [System Power Control]
(2)
Window Operations
1.
Select the power control item by radio button and then click the [Apply] button.
Dialogue box is displayed for confirmation
2.
Click the [OK] button.
The power supply is controlled according to the selected information
[Message]
This section describes the messages to be displayed on this window.
Message Number
I_00013
Setting completed.
Can't control system power under maintenance. Release maintenance mode.
E_00069
E_00077
Partition#xx cannot execute Power On.
E_00078
Partition#xx cannot execute Power Off.
E_00100
Failed to set the System Power Control
E_00101
Unable to power on the partition#%aa due to CPU mismatch between SBs.
E_00107
Unable to power on the chassis.
E_00108
Unable to power off the chassis.
E_00109
Unable to force power off.
I_00212
System Power Control cannot be executed because the system is under
maintenance.
E_00422
Unable to power on the partition#%aa due to CPU composition abnormal.
E_00482
Unable to power on the partition#%aa due to DIMM composition abnormal.
E_00491
Unable to power on the partition#%aa due to DIMM does not satisfy requirements of
Mode.
E_00517
Unable to power on the partition#%d due to abnormal SB composition.
W_00587
Unable to execute Power Control because the firmware is updating.
W_00588
Unable to execute command because the power control operating.
For details on the messages displayed on the window, see
(CA92344-0540CA92344-0540).
In case of multiple errors, 'multiple errors' message appears in the warning dialogue box.
Description
Message
PRIMEQUEST 2000 Series Message Reference
93
CA92344-0539-04

Advertisement

Table of Contents
loading

Table of Contents