1-3

Server Chassis Features

System Power

The HX2560 M1/HX2560 M2 features a high-efficiency, redundant 1800W power supply
composed of two separate power modules. This power redundancy feature allows you to
replace a failed power supply without shutting down the system. See Chapter 6 for details.

SATA Subsystem

The HX2560 M1/HX2560 M2 includes ten 2.5" drive bays, which may be used to house
hot-swap SATA drives.
Note: If you use RAID 0, 1, 1E, 1+0, 5, 5+0, 6 or 6+0, a RAID controller card is
required. When the RAID controller card is installed, SATA drives can be
installed in Bay 0-7
To provide power for the HDD backplane, connect the JPW11 header on the
serverboard to both 4-pin connectors on the HDD backplane using SATA cables.

Front Control Panel

The control panel provides a system monitoring and control interface. LEDs indicate
system power, HDD activity, network activity, and a system overheat/fan fail/ UID LED. A
main power button and a system reset button are also included.

Cooling System

The HX2560 M1/HX2560 M2 has an innovative cooling design that includes five 8-cm
heavy-duty fans. The power supply modules also include a cooling fan. All chassis and
power supply fans operate continuously.