Power On - Fujitsu PRIMEQUEST 2000 Series Tool Reference

Hide thumbs Also See for PRIMEQUEST 2000 Series:
Table of Contents

Advertisement

MMB CLI (Command Line Interface) Operations
2.2 Setting Commands

2.2.7 power on

Turn on the power supply of the entire system or the specified partition.
When the partition specified by the parameter is not configured, the partition which is not configured is
ignored.
When the power supply for the specified partition is already turned on, processing for such partitions is not
done.
Partition Operator can operate only the partition to be managed.
When the parameter which contains the partitions other than those to be managed is specified, an error
message is displayed and the specified partition cannot be operated.
Privilege: Administrator, Operator, Partition Operator (Only the partition to be
managed)
(1)
Input format
power on {partition} [ all | <partition#> [, | -] <partition#>]
(2)
Option
Partition: Turn on the power of the partition which specifies the partition number.
When there is no power supply to the chassis, before turning on the power of the partition, turn on
the power supply of the chassis and then turn on the power supply of the specified partition.
This parameter is optional. The default parameter is processed as the specified partition
parameter. Therefore, it is necessary to specify the partition.
Partitions are specified as follows.
(3)
Usage example
None
all (All defined partitions) specified
Specifies Partition numbers by delimiting with comma
Specifies with the range of partition number