Saturn KDB - 161 GOM Manual page 92

Kdb-gom series
Table of Contents

Advertisement

No
14
Unplug the boiler from the electric outlet.
Open the front cover.
Close the water pipeline.
Separate the board holding the ignition transformer and the air pressure switch.
Separate the fan unit.
Separate the pin connecting the hot water sensor and the hot water heat exchanger and the pin connecting the
hot water inlet and the connection.
Separate the hot water sensor.
Separate the water valve by taking out the hot water sensor and removing the connecting pin from the water
valve.
Fix the water valve to the hot water sensor and insert the connecting pin.
Insert the connecting pin into the hot water sensor.
Fix the fan unit.
Fix the board holding the ignition transformer and the air pressure switch.
Open the water and check for water leak.
Plugs the power cords into the outlet check the operation. if everything is fine, close the front cover.
Plug the boiler into the outlet.
1. Check for water leak after assembly.
2. Make sure the connecting jack is assembled correctly.
3. Make sure the O-ring is assembled correctly.
Part name
Replacement steps
Caution
- 92 -
KDB-GOM
Hot water flow switch
Series

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kdb - 251 gomKdb - 201 gomKdb - 301 gom