No
11
Unplug the boiler from the electric outlet.
Open the front cover.
Separate the ignition transformer's two high voltage cords connected to the electrode from the flame sensor
wire.
Unscrew the two screws fixing the electrode.
Separate the electrode from the boiler
Fix the electrode to the boiler.
Fix the electrode by screwing the two screws
Connect the ignition transformer's two high voltage cords and the flame sensor wire to the electrode.
Close the front cover of the boiler.
Plug the boiler into the electric outlet.
1. Check whether the fixation is correctly done and spark production is good.
2. Make sure the connecting jack is correctly connected.
Part name
Replacement steps
Caution
- 89 -
KDB-GOM
Electrode assembly
Series