Baked-In Beauty; System Timer; Room Thermostat Fr-5; Performance Indicator - Saturn KDB - 161 GOM Manual

Kdb-gom series
Table of Contents

Advertisement

C. Baked-in Beauty
The high quality porcelain finish is bake on and keeps the exterior looking new and lustrous for years to come.
D. System Timer
Save energy during times the home is unoccupied. Just set and activate the timer and leave. The unit turns off for
pre-programmed intervals until you return.
E. Room Thermostat FR-5
Convenient and accurate, large digital display is easier to read, easier to use. Our new room thermostat gives the
consumer digital control over several heating function.
F. Performance Indicator
With the use of the FR-5 electronic room thermostat, the (LED) will conveniently display the current operating
condition of the unit such as temperature of heating water, room temperature, normal operation, etc.
G. Continuous-Discharge Ignition(C.D.I.)
Direct ignition design requires no wasteful pilot burner and offers fuel savings.
H. Combustion Safety Protection
If the unit fails to ignite after the "ON" switch is pressed, or if the flame is extinguished due to a gas shortage, the
flame sensor will shut down the unit.
I. Always Balanced Operation
Despite fluctuating wind conditions, changes in atmospheric pressure and other external disturbances, the
variable-speed combustion blower provides steady performance.
J. Exhaust Safety Protection
While operating, the exhaust-discharge fan is continuously monitored. The units will be immediately stopped to
prevent fumes from entering the home if the wind gusts become excessive or if the flue exhaust has been clogged.
K. Smart Re-Start
Should the unit's flame fail due to strong winds or temporary low gas pressure, the unit will automatically restart. In
cold weather climates, manual resets could cause freeze damage.
L. Safety Protection during Power Outages
When the power fails, the gas is automatically shut down and the units are stopped.
M. Automatic Fill & Refill
If for any reason the water level in the system drops to an unsafe level, makeup water will automatically fill to the
appropriate levels.
N. Automatic Air Bleed
Each unit has 2 built-in air bleed devices. One is manual and used for quick fill and venting convenience; the other
is air-activated and operates and automatically.
O. Removal of Impurities
Each unit come equipped with a built-in, clearable, heavy duty, particulate water filter for trapping impurities and
preventing the clogging of pipes. This is a maintenance item.
P. Air-Ratio Controller
Air ratio is monitored, adjusted and controlled prior to and during each operating cycle and will automatically adjust
the combustion rate. The air-ratio controller guarding against unsafe operating conditions also senses excessive
gusts of wind filling the flue system.
Q. Proportional Temperature Control
This control is designed to continually analyze water flow and usage while maintaining the outgoing water at a
constant, even temperature.
- 3 -
KDB-GOM
Series