Specifications; Kyungdong Boiler Specifications - Saturn KDB - 161 GOM Manual

Kdb-gom series
Table of Contents

Advertisement

1.2 Specifications

GAS WALL-MOUNT
FRONT
View
A
B
REAR
View
A
C
SIDE View
(LEFT)
(wall)
C
SIDE View
(RIGHT)
(wall)
E
F
G D
BOTTOM
View
B
(front)
TOP
H
View
( wall )
KDB - 161 / 201 / 251 / 301 GOM
Residential Gas Hydronic Heating System
MODEL RANGE : 16,000 ~ 30,000 kcal/hr
GAS FIRED, WALL-MOUNTED, MULTI-PURPOSE, HYDRONIC HEATING SYSTEMS
---- KEY FEATURES
Full, Dual Function Heating Design.
Natural and Propane Gas Models.
Pow er-Vent, 2-Pipe Combustion Process.
Modulating Gas for Precision Temperatures.
Built-in Circulation Pump Assembly .
Built-in Ex pansion Tank.
Built-in Freeze Protection.
Digitally Controlled, Full-Logic Thermostat.

KYUNGDONG BOILER SPECIFICATIONS

MODEL NUMBER
Function
CENTRAL HEATING WATER
Construction of Heat Exchanger
Heat Output
Max.Efficiency
Temperature Setting Range
Maximum Working Pressure
Pre-Charged Expansion Tank
Circulation Pump
Freeze Protection Device
DOMESTIC HOT WATER
Heat Output
Max.Temperature Setting
Continuous DHW production
Continuous DHW production
Continuous DHW production
Continuous DHW production
Maximum Working Pressure
OTHER DATA
Gas Type
Gas Consumption - LP
Gas Consumption (natural gas)
Gas Inlet Supply Pressure
Manifold Pressure
Usage (Heating & Hot Water)
Water Storage Capacity
Power
Power Consumption
Ignition
NOx Emissions
(Ref:0%, O
Temp. of Exhaust Gas
WEIGHT AND DIMENSIONS
Net Weight
(lbs)
A Physical Dimensions: Height
B
Width
C
Depth
D Connection: Gas Inlet
E Connection: Heating Water
F Connection: Domestic Hot Water
G Connection: Primary Power
H Flue Diameter (Intake / Exhaust)
Specif ications subject to change without prior notif ication
N - 2865 PELLISSIER PLACE - WHITTIER, CA 90601 - (562) 463-0880
Prov ides Hi-Temp Water for Heating the Home.
Prov ides Hot Water for Bathing & Washing.
Controls Both Water Functions Separately .
On-Demand Hot Water Deliv ery .
Compact, Space-sav ing Design.
Quiet, Vibration-Free Operation.
Limited Warranty on Heat Ex changer
w ith 1-Year on Parts.
161 GOM
6,400 ~ 16,000
(kcal/hr)
(%)
82
( )
2
(kgf/cm
)
(liter)
6.5
6,400 ~ 16,000
(kcal/hr)
( )
10.7
(liter)
8
T = 33
(liter)
6.7
T = 40
(liter)
5.3
T = 50
(liter)
2
(kgf/cm
)
1.58
(kg/hr)
(kcal/hr)
19,000
(natural: kPa)
(min - max)
(kPa)
0.16 ~ 0.92
(liter)
0.7
(volts/cycle)
(watts)
in flue gas natural gas, ppm)
2
( )
31
(mm)
630.0
(mm)
485
(mm)
235
15A, 1/2"
Supply/Return
Supply/Return
(AC220V-50Hz)
(mm)
- 4 -
KDB-GOM
Series
201 GOM
251 GOM
301 GOM
Combo Boiler
Stainless Steel / Copper
8,000 ~ 20,000
10,000 ~ 25,000
12,000 ~ 30,000
82
83
40 ~ 80
3
6.5
8.5
Self Priming
Thermistor
8,000 ~ 20,000
10,000 ~ 25,000
12,000 ~ 30,000
80
13.3
16.7
10.0
12.5
8.3
10.4
6.7
8.3
17.5
Liquefied Petroleum (L.P.) or Natural Gas
1.98
2.48
23,700
29,700
0.98 ~ 2.45
0.16 ~ 0.96
0.25 ~ 0.94
0.14 ~ 0.96
Dual
0.7
0.8
AC 220V-50Hz
120 ~ 160
ELECTRONIC
28 (less than)
150 (less than)
31
39
630.0
685.0
485
525
235
250
15A, 1/2"
20A, 3/4"
20A, 3/4"
20A, 3/4"
15A, 1/2"
15A, 1/2"
70 / 75
84
8.5
20.0
15.0
12.5
10.0
2.97
35,600
0.8
39
685.0
525
250

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kdb - 251 gomKdb - 201 gomKdb - 301 gom

Table of Contents