4.13 Power Transformer

Function

Power Requirement

Structure
- Supply the power source to boiler.
Input Rating
Output Rating
Casing
Cable
- 24 -
KDB-GOM
AC 220 V , 50 / 60 Hz
AC 220 V
# 8-BLACK, # 9-GRY
AC 34.0 V
# 2-RED, # 6-RED
AC 18.4 V
# 1-ORANGE, # 5-BLUE
AC 12.0 V
# 4-WHITE, # 7-BROWN
Non-Combustible ABS
Silicon
Series