Saturn KDB - 161 GOM Manual page 66

Kdb-gom series
Table of Contents

Advertisement

8 - 1
L.P . Gas Container
No
Symptoms and Causes
Flame failure in combustion occurs when
the flame disappears during combustion
10 times consecutively.
1
Gas supply pressure is not right.
# 12
Failure
<Fig. 1>
-
Check gas supply pressure
LNG: 100 ~ 250 mmAq.,
LPG: 230 ~ 330 mmAq
- Check whether LPG is empty when gas
pressure is low and if it is replace with a new
full container.
- In cold seasons, the gas container may not
supply gas normally. Warm up the container
first.
- LPG hose may be too long (more than 3 m) or
have fold down. Replace the hose or shorten
it.
- The gas meter may be defective. Contact the
gas company for replacement.
- Gas initial supply pressure of 200 mmAq may
fall down under 100 mmAq after combustion.
In that case contact the gas company.
- 66 -
KDB-GOM
Flame failure in combustion
KyungDong
Gas Meter
Solutions
Series
<Fig. 2>
Reference
<Fig. 1>