6. Troubleshooting

6.1 Troubleshooting - Error Codes

Error Code
01 / Overheat
02 / Low Water Level
03 / Ignition Failure
04 / Flame Sensor
05 / Heating Sensor Wire
Disconnected
06 / Heating Sensor Short
Circuit
07 / Hot Water Sensor Wire
Disconnected
08 / Hot Water Sensor Short
Circuit
09 / Fan RPM Failure
10 / Air Pressure Switch Failure
11 / Water level Detection
Failure
12 / Flame Failure
13 / Heating Water Switch
Failure
14 / Gas Alarm (Optional)
15 / MICOM Failure
16 / Mechanical Overheat
17 / DIP Switch Setting
Cause
Clogged / Reduce flow in heating system
Circulating pump failure
No water in system / Pump failure
No make up water supply
Water fill valve failure
Check ignition transformer
Check high limit switch / fuse
No gas supply
Air pressure switch tripped
Low gas pressure
Fan failure / Airflow pressure switch
Check molex connection
Sensor failure
Check molex connection
Sensor failure
Fan failure
Check speed control
Fan failure
Air flow switch failure
Blocked flue
Excessive wind gusts
Check water fill valve
Low gas pressure
Fan failure / Air flow sensor
Blocked flue
Faulty switch
Check if connected (Red / Black wire)
Pump motor overheat
Fan motor overheat
Incorrect settings
- 49 -
KDB-GOM
Troubleshooting
Check strainer clean
Check system for air rate
Check pump for operation –220V AC = 1 Amp
Check system / Check pump
Check system
Check system 5V DC- input signal
Input 220V AC
N/C contacts
Check gas connection
Check gas valve
Check tube for connection
Check flue for blockage
Check gas valve 220V AC
Check gas pressure
Check fan for operation
Check switch, flue for obstruction
Re - connect
Check voltage Pin #15&5 on 21Pin connector,
main controller 5V DC
Re - connect
Check voltage Pin #19&8 on 21Pin connector,
main controller 5V DC
Check fan for operation. Input voltage 7 – 40V
DC. Red-Black wires
Check fan for operation
Check tube connection
Check voltage 5V DC
Check flue for blockage
Check flue termination - relocate
Voltage 5V DC
Check gas pressure
Check gas valve
Check fan for operation
Check tube on air flow sensor
Check air flow sensor – 5V DC
Check flue for obstruction
Check voltage – 5V DC on Pin #10 on 13 pin and
Pin #17 on 21 pin connectors
Re – connect
Check gas supply
Check voltage 5 – 20V DC
Check connection from t-stat to unit
Replace t-stat or micom controller
Check for pump operation 220V AC, approx 1A
(dependent on flow rate)
Check fan for operation
Check rotation
Check setting especially
Series