Saturn KDB - 161 GOM Manual page 62

Kdb-gom series
Table of Contents

Advertisement

4
No
Symptoms and causes
Failure code # 05 is displayed when the
heating sensor is short circuited or
disconnected.
1
Bad connection between the heating
temp. sensor and the harness connecting
the controller.
2
The heating temp. sensor is short-
circuited therefore unable to detect.
# 05
Failure
Main Controller
- Reconnect the connecting harness terminal.
- The heating temp. sensor is defective and has
to be replaced.
- If there is nothing wrong with the above, the
main controller is defective and has to be
replaced.
- 62 -
KDB-GOM
Disconnection of the heating temp. sensor
Heating
Sensor
Check connection
Solutions
Series
Temperature
<Fig. 1>
Reference
<Fig. 1>

Hide quick links: