Tester positive probe
Pink/White "1"
Negative tester probe
Black/Blue "2"
b. Set the main switch to "ON".
c. Measure the intake air temperature sensor
voltage.
LLLLLLLLLLLLLLLLLLLLLL
2. Install:
Intake air temperature sensor
G
EAS15B3019
CHECKING THE V-BELT RESET COUPLER
1. Check:
V-belt replacement indicator reset coupler for
G
continuity
No continuity → Replace
MMMMMMMMMMMMMMMMMMMMMM
a. Connect the pocket tester (Ω × 1) to the
V-belt replacement indicator reset coupler as
shown.
Pocket tester
90890-03112
Analog pocket tester
YU-03112-C
Tester positive probe
Black "1"
Negative tester probe
Black "2"
ELECTRICAL COMPONENTS
LLLLLLLLLLLLLLLLLLLLLL
2. Check:
V-belt reset coupler voltage
G
Out of specification → Replace.
V-belt reset coupler voltage
12V
MMMMMMMMMMMMMMMMMMMMMM
a. Connect the pocket tester (20V DC) to the
meter assembly coupler (wire harness side)
as shown.
Pocket tester
90890-03112
Analog pocket tester
YU-03112-C
Tester positive probe
Light green "1"
Negative tester probe
Black/White "2"
b. Turn the main switch to "ON".
c. Measure the voltage of gray "1" and black "2"
at the meter assembly coupler.
LLLLLLLLLLLLLLLLLLLLLL
8-121
1
2
1 2