Any attempt to remove an installed TPM from the system board breaks or disfigures the TPM security
rivet. Upon locating a broken or disfigured rivet on an installed TPM, administrators should consider the
system compromised and take appropriate measures to ensure the integrity of the system data.
When using BitLocker, always retain the recovery key/password. The recovery key/password is
required to enter Recovery Mode after BitLocker detects a possible compromise of system integrity.
HP is not liable for blocked data access caused by improper TPM use. For operating instructions, see the
encryption technology feature documentation provided by the operating system.

Installing the Trusted Platform Module board

WARNING:
internal system components to cool before touching them.
Power down the server (on page 20).
1.
Remove all power:
2.
Disconnect each power cord from the power source.
a.
Disconnect each power cord from the server.
b.
Do one of the following:
3.
Extend the server from the rack (on page 20).
o
Remove the server from the rack (on page 22).
o
Remove the access panel (on page 24).
4.
If an expansion board is installed in the secondary PCI riser location, remove the board.
5.
CAUTION:
the TPM security rivet. Upon locating a broken or disfigured rivet on an installed TPM,
administrators should consider the system compromised and take appropriate measures to ensure
the integrity of the system data.
Install the TPM board. Press down on the connector to seat the board
6.
page 13).
To reduce the risk of personal injury from hot surfaces, allow the drives and the
Any attempt to remove an installed TPM from the system board breaks or disfigures