Points to notice for Disassembly and Assembly

Caution:

① In disassembly/(re)assembly, be sure to use conductive mat (J5033) and wrist strap (J5033-5), in
order to protect electric parts from static electricity.
   ② Before disassembling, be sure to remove batteries or AC power cord.
   ③ In disassembling, be sure to memorize the processing state of wires and FPC, screws to be fixed and
their types, etc.
   ④ The low-pass filter of the image PCB is easily damaged. Handle it very carefully.

  Points to notice for Lead-free solder products

・Lead-free solder is used for this product.
 ・For soldering work, the special solder and soldering iron are required.
 ・Do NOT mix up lead-free solder with traditional solder.
Caution:
When "Separation of Front body from Rear body", "Disassembly of CCD/FPC unit" and
"Disassembly of Bayonet" are performed, be sure to carry out "RESET AF-DEFOCUS
COMPENSATION" of the D200 adjustment software after assembly.
WARNING
警告
Take extra care not to get an electric shock when detaching
内部に高電圧部あり。カバーを外す時は感電に注意すること。
covers.
After removing covers, b e sure to discharge the main
カバーを外した後は、修理指針の指示に従ってメインコンデン
condenser according to the instructions of repair manuals .
サーの放電を必ず行うこと。