9-3. Pixel defect compensation - white point
 ・Check the environmental temperature (approx. 20-25°C.).
 ・Provide the power for the camera via AC adapter.
 ・Reset "Custom setting".
 ・Set "PTP" mode by Setup menu.
 ・Set the focus mode to M, exposure mode to M, and the exposure compensation to "0" of the camera.
 ・Connect the camera and PC via USB cable.
 ・Click "WHITE POINT" of "PIXEL DEFECT COMPENSATION" of the menu.
 ・Cap the camera with the body cap or lens cap to shield light from the mount.
 ・When the adjustment starts, pixel defects are detected, displaying the number of pixels and addresses.
 ・After confirming the above, click "X" button.
 ・When it is completed, "OK" is displayed.
9-4. Getting of reference values
 ・Set the color viewer luminance to LV13 equiv.
 ・Provide the power for the camera via AC adapter.
 ・Reset "Custom setting".
 ・Set "PTP" mode by Setup menu.
 ・Set the focus mode to M, exposure mode to M, and the exposure compensation to "0" of the camera.
 ・Connect the camera and PC via USB cable.
 ・Select "SENSITIVITY, RATIO REFERENCE VALUE CALC" of the menu on screen.
 ・The current reference value is displayed on screen.
 ・Click "SENSITIVITY, RATIO REFERENCE VALUE CALC".
 ・The calculation of the sensitivity reference value starts. The message to set conditions is displayed.
 ・Attach the tool lens (Aperture F8) and ND filter (ND 8× 1 + ND 4 ×1)to the camera.
 ・Get the camera closest to the center of the illuminated surface of the color viewer.
 ・The adjustment starts. When it is completed, the software goes on to the sensitivity ratio reference value.
 ・Attach the tool lens (Aperture F8)(Remove ND filter).
・The adjustment starts. When it is completed, the sensitivity and sensitivity reference values are stored in
the standard setting file (STD, DAT).
・After this procedure, when the shooting image adjustment is made, the sensitivity and sensitivity ratio that
were calculated this time are used.
※ Calculate the sensitivity and sensitivity ratio reference values once in about every 3 months, and when the
fluorescent of the color viewer is replaced.
9-5. Reading of RISC version
 ・Provide the power for the camera via AC adapter.
 ・Set "PTP" mode by Setup menu.
 ・Connect the camera and PC via USB cable.
 ・Click "READING OF RISC VERSION" of the menu on screen.
 ・RISC version is displayed.
- A63 ・
-
INC
VBA13001-R.3677.A